20170505162745.pdfla L-D c-;Lo I (o � 05 56 Z- / 6 -7 72- lee c e Aldrich +Associates, Inc. C 0 N S T R U C T 1 0 N S P E C I A L I S T S April 13, 2017 Bob Gardner, Senior Project Manager Mayes Testing Engineers, Inc. 20225 Cedar Valley Road, Suite 110 Lynnwood, WA 98036 Subjeft. 16-765 BARC Final Inspection Letter Bob: The work on this project was performed in conformance with the Permit Drawings prepared by Freiheit & Ho Architects and CG Engineers dated 9/16/16 and approved by the CRY of Edmonds. Special inspections required on this project were listed as adhesive anchors, concrete and structural steel on SIA. The permit documents only called for adhesive anchors at the new column base plates for the columns that were replaced along the storefront. These adhesive anchors were re -engineered as mechanically fastened, thus eliminating adhesive anchors from the project permit documents. The adhesive anchors that were inspected by Mayes were the dowels that Aldrich and Associated inserted into the building perimeter slab, where possible, as part of Aldrich's standard practice for new slabs on grade, although not required by the permit documents. Additionally, because portions of the slabs were to remain to be replaced in a future phase of the project, the dowels were not extended into the slab on the north and east slabs. Dowels could not be inserted into 8" un-grouted CMU at the north portion of the south wall. The dowels are not required for gravity slabs on grade, nor were required in the permit documents, but since they are "adhesive anchors" they fall under the purview of Special Inspections. The permit documents call for the removal and replacement of existing slab on grade with new. The exisfing slab was unreinfbrced. The new slab was a bidder design by contract as follows: 04" thick with #4 bar@ 12"O.C. each way," The concrete mix design used was 5,000 psi concrete. The minimum compressive requirement for interior concrete slabs on grade is 2,500 psi as per IBC 1904.2.2. There was not any structural steel installed as part of this project. All of the above work was observed to be performed in conformance with the permit documents, the IBC and Aldrich and Associates enhanced standard practices. We have attached the pertinent permit documents for your review and expect to receive a final inspection letter from your firm on behalf of the Owner, BARC Properties LLC, so that we are granted occupancy by the City of Edmonds. Should you have any question, concerns or require and more information, please do not hesitate to contact our office at your convenience. Sincerely, George Bruc� Project Manager 810 — 240M Strieet BE Ph (425)4&-1-1313 www.eldrich-assoc.com Bothell, WA 98021-9397 Fax (425)4W1018 Lie No. AL-DR-LA*202RU Predictable Results... Every Time GENERAL OBSERVATION REPORT MAYES TESTING ENGINEERS, INC Report Number: M7161772.0001 Service Date: 04/13/17 Report Date: 04/18/17 Client Veterinary Cancer Specialty Care, PLLC Attn: Chelsea Tripp 23200 Edmonds Way Edmonds, WA 98026 20225 Cedar Valley Rd Ste 110 Lynnwood, WA 98036-6365 425-742-9360 Project BARC Properties 8401 Main Street Edmonds, WA Proiect Number: M7161772 Permit No.: BLD-20160950 Weather: I N/A Samples: N/A Received the attached letter from Aldrich and Associates Project Manager, George Bruce, regarding open items noted in Mayes Testing Engineers inspection reports dated 12/23/16 and 12/28/16 regarding epoxy without special inspection, access to approved construction drawings and concrete mix design approval. Per the attached letter, the work was performed per the drawings submitted to the City of Edmonds and Aldrich and Associates enhanced standard practices. It is approved to issue the Final Letter for proprietary anchor installation and reinforced concrete. To the best of our knowledge, all items inspected today are in conformance with approved plans and specifications. Services: Project management Mayes Testing Engineers, Inc. Rep.: Robert Gardner Reported To: Aldrich and Associates, Inc. Contractor: Aldrich and Associates, Inc. Report Distribution: (1) Veterinary Cancer Specialty Care, PLLC, Chelsea Tripp Reviewed By: /A, Jzc� Robert Gardner Senior Project Field Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CT0001, 10-16-13,R- 10 Page I of I