Loading...
20170530104956.pdfE-- —.- Fo j DEVELOPMENT S E N 1 t' R I H 0 U , N L � i , I V , , . � 7 7771 EDMONDS MEMORY CARE PERMIT #BLD20150032 21006 72ND A VEW., EDMONDS, WA REVISION 10 DATED 05-11-17 4�3 REVISION MAY 17 2017 BUILDING DEPARTMENT CITY OF EDMONDS Enclosed you will find two copies of the revised plan sheet A5.Oa showing roof ventilation and the spec sheet for roof ventilator. We revised the venting calculations and the power ventilator in the middle of the roof. The inspector wanted to see how we are venting the roof and wanted the mechanical engineer to verify the ventilator which he has done and why we changed it. If you have questions or need anything else, please advise. Thank you, Jeff Yates Partner and Vice President RJ Development jeff@rjdevelopment.com 360-918-6037 RJ Development 401 Central St SE — Olympia, WA 98501 (360) 528-3343 — www.ridevelop!neilt.com EDMONDS MEMORY CARE PERMIT #BLD20150032 21006 72ND AVE W., EDMONDS, WA RE, VISION 10 DATED 05-11-17 MAY 17 2017 DEVELOPMENT SERVICE3 REVISION MAY 1-1 201-1 BUILDING DEPARTMENT CITY OF EDMONDS Enclosed you will find an additional document to go with the submittal already made for the roof ventilation of the Edmonds Memory Care building. It is to letter from the mechanical engineer regarding the proposed attic ventilation fan. If you have questions or need anything else, please advise. Thank you, Jeff Yates Partner and Vice President RJ Development jeff@rjdevelopment.com 360-918-6037 RJ Development 401 Central St SE — Olympia, WA 98501 (360)528-3343—wwwAdeve1op ient.corn DUMAIS 0 ROMANS CONSULTING MECHANICAL ENGINEERS Guy Dumais, P.E. Jeff Romans, P.E. Engineered Environments HVAC Engineering PipingSystems Construction Administration Life Cycle Cost Analysis May 15, 2017 RJ Devlopment Services 401 Central St. SE Olympia, WA 98501 Attn: Jeff Yates Re: Edmonds Memory Care Facility Jeff, RLTvjSjohj� MAY 1'? 2017 BUILDING CITY 0FDLz"AnTA4EN7 EDA40NDS Regarding the Edmonds Memory Care Facility located at 21006 72 Avenue NW in Edmonds, Washington: I have reviewed the proposed attic ventilation solution proposed on Sheet A5.0 along with the cut sheet provided for the proposed attic ventilation fan. My calculations indicate that the proposed system will be self -balancing and meet the intent of the International Building Code for attic ventilation. Sincerely, Dumais - Romans, Inc. �tp&"'V'o Jeff Romans, P.E. North 2 10 University Road — Suite 100 Spokane Valley, Washington 99206 Phone (509) 893-9646 Fax (509) 893-9648 e-mail guyj2dumaisromans.com or