Loading...
20170605111615.pdf'-Resporvs:�?� -rn <-8te� (--otwvr)-� 1 RESUB JUN 0 5 2917 BUILDI - �R TMENT 'EZ CITY OF ED ONDS Randall J. Munson Building Designer 17713 151 Avenue NE— Suite 102 Shoreline, Washington 98155 (206) 349-4551 May 26, 2017 Chuck Miller, Plans Examiner City of Edmonds, Building Division 121 5th Avenue North Edmonds, Washington 98020 18626 94th Avenue West Re. Plan Check BLD2016-1610 Project Address: 753 Bell Street The following is an item by item response to your correction letter dated April 11, 2017 Sheet SP-01 — Site Development Plan 1. See sheet A-8 for fire area calculation. As measured to the inside face of the building the square footage is 2,999 square feet. Sheet A-1, Site Plan, Project Data, Index of Drawings and Legend. 2. a. I've included sheet A-8 with this submittal. It is a fire area calculation. b. I've included sheet A-9 with this submittal. It is the general note. Sheet A-4, Main Level Floor Plan and Key Notes 3. Key note #37 updated to comply. 4. Detail removed to comply. 5. Key note #19 updated to comply. 6. Main Level Floor Plan a. Added a listing of the energy credits to Sheet A-1 to comply. b. Added a listing of the energy credits to Sheet A-1 to comply. C. Added a listing of the energy credits to Sheet A-1 to comply. d. Added a listing of the energy credits to Sheet A-1 to comply. e. Key Note#21 revised to comply. f. Revised Keynote #36. Sheet A-5 Upper Level Floor Plan 7. Key Notes a. Corrected Key Note #19 to comply. b. Added a listing of the energy credits to Sheet A-1 to comply. C. Corrected Key Note #38 to comply. 8. Upper Level Floor Plan a. Added a listing of the energy credits to Sheet A-1 to comply. b. Added a listing of the energy credits to Sheet A-1 to comply. C. Corrected Key Note #36 to comply. Page Two Plan Check BLD2016-1610 Project Address: 753 Bell Street Sheet A-7 Window Schedule and Details 9. Detail #5 Corrected to comply. 10. 1 have corrected the Window Schedule to agree with both Floor Plans. Sheet A-8-Now A-9 - General Notes: 11. Deck design load corrected to comply. 12. Removed note to comply. 13. Revised note to comply. 14. Revised note to comply. 15. Revised note to comply. 16. Energy & Ventilation per WSEC 2015. a. Added a listing of the energy credits to Sheet A-1 to comply. b. Removed note #17 & Added a listing of the energy credits to Sheet A-1 to comply C. Added a listing of the energy credits to Sheet A-1 to comply. Sheet S-1 Design Loads and Details: 17. Corrected deck live load to 60 psf. Sheet S-2 Foundation Plan and Details: 18. Foundation Plan a. Drawing has been Signed/Stamped by Wendell Reed. b. Keynote #21 has been corrected on Sheets A-4 & A-5. C. Added missing cross referencing to comply. Sheet S-3 Framing Plans and Details 19. a. Lateral load transfers were responded to on Sheet A-4, Shearwall Wall Plans. b. I have included with this submittal an entire new beam calculation. Sheet S-4 Lateral Plans, Shearwall Schedule and Details 20. Upper Level Shearwall Plan a. Added missing detail to comply. b. Added and referenced detail #6, Sheet Ss -I C. Added references for upper and lower connection. d. East wall of Bonus Room stacks directly over east wall of Great Room. e. Added references for upper and lower connection. f. Added references for upper and lower connection. 9. West wall of Bedroom 3 stacks directly over west wall of Dining Room. h. North wall of Bedroom 3 stacks directly over the north wall of the Dining Room. i. The west wall of the Master Bath stacks over a PSL. j. Added references for upper and lower connection. 21. Main Level Shearwall Plan a. Added missing detail to comply. b. Added missing reference. C. Added missing reference and added additional callouts on #1/S-3. d. The allowable value for 8" stem wall, end condition & cracked concrete is 3500 lbs. which is greater than the actual load of 3224 lbs per conversation with Wendell. See attached page of Simpson catalog for reference. Please feel free to contact me directly at (206) 349-4551 if you have any additional concerns. Respectfully Ge, 11-6 Randall J. Munson Building Designer V 0. LSTHD/STHD Strap -Tie Holdowns (cont.) Tension Loads for STHID Installations SIMPSON Strong -Tie Wind and SDC A&B - Allowable Tension Loads for DF/SP/SPFIHF (160) Min. Sternwall (in.) Model No. Strap Length (L) le (in.) Required Nails Non -Cracked Cracked Code Ref. : 7StandardTRim Joist Standard (in.) Rim Joist (in.) Midwall Corner Endwall Midwall Corner Endwall LSTHD8 LSTHD8RJ 18% 321/e 8 (20) 16d sinkers 3,115 2,700 1,690 2,675 2,320 1,455 6 STHD10 STHD10RJ 24% 381/8 10 (24) 16d sinkers 3,820 3,820 2,050 3,140 3,140 1,705 STHD14 STHD14RJ 2 6 I/B 39% 14 (30) 16d sinkers 5,150 5,150 3,200 5,150 5,150 3,200 125, LSTHD8 LSTHD8RJ 18% 32% 8 (20) 16d sinkers 3.115 2,700 2,230 2,675 2,320 1,915 F 8 STHD10 STHD10RJ 24% 381/8 10 (28) 16d sinkers 41755 4 1 120 3,145 4,195 3,500 2 ' 585 STHD14 I STHD14RJ 2 6 1A 39% 14 1 (30) 16d sinkers 5,345 5,345 1 4,210 5,345 5,345 4,2101 SDC C-F Allowable Tension Loads for DF/SP/SPF/HF (160) Min. Stemwall (in.) Model No. Strap Length (L) le (in.) Required Nails Non -Cracked Cracked Code Ref. Standard Rim Joist Standard (in.) Rim Joist (I n.) Midwall Corner Endwall Midwall Corner Endwall _STHD8 LSTHD8RJ 181/8 321/8 8 (16) 16d sinkers 2,270 2,090 1.220 2,250 1,950 1,220 6 STHD10 STHD10RJ 24% 381/8 10 (18) 16d sinkers 2,750 2,750 1,615 2,640 2,640 1,435 STHD14 STHD14RJ 261/A 395/s 14 (22) 16d sinkers 3,695 3,695 2,685 3,695 3,695 2,685 125, LSTHD8 LSTHD8RJ 18% 321/8 8 (16) 16d sinkers 2,615 2,125 1,635 2,250 1 1.950 1,610 FL 8 STHD10 STHD10RJ 24% 381/8 10 (20) 16d sinkers 1 3,400 2,940 2,295 3.400 2,940 21,175 STHD14 STH014RJ 2 6 IA 39% 14 1 (24) 1 6d sinkers 1 3,815 3,815 3,500 3,815 3,815 3,500 1 1 . Allowable loads are for wind or seismic loading. Nail quantities reflect an increase for duration of load with no further increase allowed, Reduce where other loads govern, 2. Concrete shall have a minimum concrete strength, Vc of 2,500 psi. 3. 1 Od common (3" long x 0. 148") or 1 Od x 21/2" (21/2" long x 0. 148") nails may be used as a direct replacement for the required nails shown in the table with no load reduction when installed directly over framing or over 1/2" max. structural sheathing. 4. Use the specified number of nails listed in table or as specified, In many cases, not all nail holes will be filled. Nail strap from the bottom up. 5. Deflection at highest allowable loads for install over wood double studs are as follows: Installed on framing: LSTHD8 = 0.089", STHD1 0 = 0. 117" and STHD1 4 = 0. 118". Installed over 1/2" maximum structural sheathing: _STHD8 = 0. 114", STHD1 0 = 0. 146" and STHD1 4 = 0. 164". 6. To obtain _RFD values for STHD holdowns, MUltifely ASD seismic load values by 1.4 and wind load values by 1.6 (1.67 for 2015 IBC). 7. Per 2009 and 2012 IBC Section 1613.1, detached one- and two-family dwellings in Seismic Design Category (SDC) C may use "Wind and SDC A&B" allowable loads. 8. Minimum center -to -center spacing is three times the required embedment (Smin = 3 x l�) for STHDs acting in tension simultaneously. Midwall install is based on 1.5 x le and distance. 9. See technical bulletin T C-SCLCLM at strongtie.com for installation on structural composite lumber posts or columns. 10. For brick ledge applications, use full loads shown for STHD1 4 installed in 8" sternwall. 11. Nails: 16d sinker � 0. 148" dia, x 31/4" long. See pp. 26-27 for other nail sizes and information. 86