Loading...
20170609163402.pdfHANSON DESIGN JUNE 2, 2017 KRISTIN HANSON RESUB 652 ALDER STREET JUN 0 7 2017 EDMONDS 98020 BuiLDING DEPARTMENT CITY OF E':DMONDS CITY OF EDMONDS CHUCK MILLER BLD 2016 - 1710 DUPLEX 7607 206 TH ST SW RESPONSE TO CORRECTION LETTER: APRIL 4, 2017 CORRECTIONS NOTED IN BLUE INK ON PLANS. (2) PAGES ADDED: NEW PAGE 4.A NEW PAGE 5 (REPLACED) SITEJ DRAINAGE 1. REFER TO CIVIL PLANS EXISTING RESIDENCE ON PROPERTY IS SELF-SUFFICIENT, WILL NOT BE SHARING UTILITIES WITH DUPLEX. 2. TABLE OF CONTENTS: MIS -NUMBERED. NOW CORRECTED. TABLE of CONTENTS: 1. SITE, TITLE 3nis 2. SURVEY 3. GARAGE, ENTRY ACCESS 4. LOWER / UPPER UNIT FLOOR PLAN 4.A FIRE ASSEMBLIES NEW PAGE (5. OLD PAGE 5 REMOVED) 5. A NEW FOUNDATION/ 1 ST FLOOR FRAMING. 6. 2 ND FLOOR FRAMING, ROOF 7. DETAILS, SECTIONS 8. ELEVATIONS, HEIGHT CALCS 9. GENERAL CONSTRUCTION NOTES NEW STRUCTURAL ENGINEERING PAGES. / NEW CALCULATIONS ENGINEER'S RESPONSE LETTER S.1 STRUCTRURAL NOTES S. 2 FOUND / SHEAR WALLS S.2.2 SHEAR WALL/ FRAMING PLAN S.3 STRUCTURAL DETAILS S 3.1 STRUCTURAL DETAILS S 3.2 DETAILS S 3.3 DETAILS SHEET 3 : GARAGE LEVEL 3. STAIRS: CHANGE CODE REFS: NOTED 4. HANDRAILS: CHANGE CODE REFS: NOTED 5. SPACE UNDER STAIRS: INTERIOR STAIRS NOW ENCLOSED WITH FIRE PROTECTION ON ALL SIDES. SEE Pg 4.A 6. FIRE ASSEMBLE BETWEEN GARAGEJ UNITS: SEE Pg. 4.A 7. GARAGE - HOUSE SEPARATION: SEE Pg 4.A 8. INTERIOR STAIR DETAILS: SEE Pg. 4.A 9. CO ALARMS: CHANGED LANGUAGE ON NOTE. 10. ATTIC ACCESS: CHANGED TO 30" HEIGHT 11. EGRESS OPENINGS NOTE: CHANGE "SILL' TO 'BOTTOM OF OPENING.' 12. WSEC : CHANGE R-30 to R-38, SINK, FLOOR, CREDITS, ETC. OWNER WILL SOON DECIDE ON HEATING, WATER HEATING. A D D E D N 0 T E: EA CH UNI T MUS T COMPL Y W1 TH SUFFICIEN T OP TIONS FROM WSEC TABLE R406.2 TO DEVELOP THAT REQUIRED PER WSEC R406.2 13. SECOND FLOOR: ALARM PLACEMENT/ SAFETY GLAZING DECK RAILING : PG 6 : 1 NEW 14. LOWER UNIT: ALARM PLACEMENT I SAFETY GLASING DECK RAILING: Pg 6 :1 NEW 15. SHEET 5 : NEW SHEET 5 . A. a - d DRAFTING ERRORS CORRECTED 16. LOWER FLOOR FRAMING SHEARS; SEE NEW PAGE 4-A. FIRE DETAILS 17. ATTIC ACCESS: CORRECTED TO 30 IN. 18. FIRE WALL: SEE PAGE 4.A b. T8 /S -3 DETAIL. NONE REQ. ER4SED. SHEET 7 SECTIONS: 19. - 21 SEE PG. 4-A FOR FIRE ASSEMBLIES, LOCATIONS. SHEET 9 SECTIONS: 22. CO ALARM LANGUAGE CORRECTED. 23. WSEC: CORRECT U-VALUES 24. REBAR: CORRECTED TO 60 ITEMS 25a - 29 SEE ENGINEER'S RESPONSE LETTER. I HOPE THESE RESPONSES ARE COMPLETE. PLEASE LET ME KNOW IF MORE IS NEEDED. KRISTIN HANSON 425-774-7129 hansondesign@hotmaii.com -- - - — - —1 t