20170712084838.pdfSNOHOMISH HEALTH DISTRICT WWW.SNOHD.ORG ,;3 c Ir.) a'6p I ("', / tr k'? Environmental Health Division July 7, 2017 RECEIVED Mike Baily LDG Architects 652515 th Avenue NW #220 112017 Seattle, WA 98117 DEVELOPMENT SERVICES Subject: Proposed Edmonds Hero Ace Hardware & Grocery, 550 5 th Avenue South, Edmonds COUNTER Dear Mr. Baily: Your plans have been reviewed with the Bules and Regulations of the State Board of Health, and with the policies of the Snohomish Health District. With the addition of the following conditions, the plans are approved. I . The conditional approval of the plans for Edmonds Hero Ace Hardware & Grocery was based upon the plans submitted April 10, 2017 and June 19, 2017 and ' menu and HACCP submitted April 10, 2017 and May 25, 2017. Any changes to these items will void this approval. 2. Three -compartment sinks must be NSF or equivalent listed with rounded corners and integral drainboards at both ends. The basins of the three -compartment sink must be large enough to fit the largest item needing to be washed. 3. An indirect waste drain (an air gap) is required for the food preparation sinks, ice machine, pop dispenser, walk-in refrigeration, and any equipment in which food is placed. Please note that a direct drain to a grease trap is not considered an indirect drain even if the grease trap is indirectly drained. 4. A reduced pressure backflow prevention device is required at the end of the copper water pipe serving the pop dispensing system prior to the carbonation device. No copper or brass pipe/fittings or other potentially corrodible material is allowed after the reduced pressure backflow prevention device. 5. Each food preparation sink must be NSF or equivalent listed with at least one integral drainboard. 6. A horizontal separation of at least 16 inches or a pony wall, from the floor to at least 16 inches above the sink basin, is required between the raw meat/poultry/seafood preparation sink and ready to eat food preparation and storage areas. 7. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required between the handwash sink and all food preparation areas. 8. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required between the handwash sink and the mop sink. 9. When splashguards (partitions and/or walls) are provided on both sides of a handwash sink the distance between the splashguards must be at least 18 inches apart (shoulder width) to allow proper access to the handwash sink. 10. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks and at the same time provide hot water to all handwash sinks. 11. Hot water must be available to all handwash sinks within 15 seconds. The hot water for the facility must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational inspection. This is required so that proper testing of the 15-second time requirement for hot water availability can be completed. 12. All food service equipment, both new and used, must be listed by the National Sanitation Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of holding food at temperature of 41 OF or below. 13. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food service establishment. Used equipment must be clean, in proper operating condition, and in good repair. Used refrigeration must be capable of holding at a temperature of 41 OF or below. 3020 Rucker Avenue, Suite 104 M Everett, WA 98201-3900 0 tel: 425.339.5250 a fax: 425.339.5254 14. All food service equipment must be listed by the National Sanitation Foundation (NSF) or equivalent for its intended use. No manufacturer name and model number was provided for the pop machine, soup pots and panini grill. Prior to the request for a preoperational inspection a manUfacturer name and model number must be provided for the pop machine, soup pots and panini grill. Equipment fOUnd not to be NSF or equivalent listed will be required to be replaced with NSF or equivalent list equipment. 15. Extra wall protection is required on walls behind all sinks. including restroom handwash sinks, and food preparation counters and tables. Sinks in corners must also have wall protection on the side walls. A 16-inch high backsplash of plastic laminate, fiberglass -reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall behind counter top equipment taller than 16 inches. Wall protection behind mop sinks must cover the entire splash zone. Plastic coated hardboard is not acceptable. 16. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw cuts and the like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as to provide a smooth and cleanable surface. 17. The ceiling above the food preparation areas must be non -perforated, nonabsorbent, smooth and easily cleanable. 18. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type surfaces are not acceptable) 19. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof bulbs. Hot hold unit heat lamps must be provided with shatterproof bulbs. 20. If the establishment continues to be in operation during the remodel, dust barriers must be installed to ensure that food protection and safety is not compromised. The establishment will be required to discontinue operations if any disruption in water, electrical, or sewer service occurs, due to the remodel. Proper handwash stations must be kept accessible and functional during all hours of food service establishment operation. 21. Plumbing must meet state and local codes. 22. It cannot be determined from the floor plan or information submitted whether or not a chemical dispensing system will be installed at the mop sink. Please note that the use of screw -on type'wye' adaptors at the mop sink faucet for use with chemical dispensing systems is prohibited. Additionally chemical dispensers cannot be connected to the mop sink faucet. The chemical dispenser must have a separate water connection. A ,sidekick' adaptor at the mop sink faucet is acceptable. 23. The ventilation system shall be installed and operated to meet applicable building, mechanical, and fire codes. A preoperational inspection is required prior to operating permit issuance and approval to open for business. At the time of inspection the construction of the food service establishment must be complete and all equipment must be in place and in proper operating condition. Incomplete construction or equipment operation will result in a $180.00 re -inspection fee. Contact the Food Program office a minimum of ' one week in advance to schedule an appointment for the preoperational inspection. The preoperational inspection will ensure compliance with the.Rules and RegUlations of the State Board of Health for Food Service Sanitation. Changes or additions to the approved plans or equipment require pre -approval from the Snohomish Health District prior to implementation of the changes. Please contact me if you have any questions. My office number is 425.339.8742 and my email address is ehaaedorn(cDsnohd.ora. Sincerely, ElaVe'Hag d�orn,RS Environmental Health Specialist Food Establishment Plan Review EH/kdc cc: City of Edmonds Building Department Retta Taffesse RS, Environmental Health Specialist