20170717083302.pdf11 * I (1RD F S 16 h, 6 U I 1. 0 0 A I A N I F Reviewer: BLD20170615 � Laughtland Residence Brad Shipley Associate Planner City of Edmonds Planning Division 121 5th Ave N Edmonds WA 98020 (425) 771-0220 ext. 1367 Brad.Shipley@)edmondswa.go 926 Walnut Street 1. Lot Area: The lot area shown includes both lots. Please only show area for lot being developed. Re -calculate lot coverage as necessary. Response: See updated Lot Coverage Calculations Sheet AO. 2. Lot Line Dimensions: Lot line dimensions shown along southern border are incorrect. Please correct. Response: See updated Site Plan Sheet AO. Reviewer: Eric Carter Plans Examiner City of Edmonds Planning Division 121 5th Ave N Edmonds WA 98020 425-771-0220 x 1389 eric.carterC@edi-nondswa.ciov 1. The energy notes indicate the home will comply with the prescriptive requirements of table R402.1.1. The home must also comply with section R406 of the Washington State energy code. Section R406 requires additional energy credits to be utilized to further benefit the energy efficiency of the home. Please select an additional 3.5 credits from table 406.2 of the 2015 Washington State energy code and add those additional credits as well as indicate the ratings of the individual appliances to the plans. I 1 S 16 N. 0 B A 1. A N V � BLD20170615 � Laughtland Residence 7/13/17 1 926 Walnut Street Response. See updated Energy Notes, Sheet A2. 2. General notes referencing smoke and CO detectors to direct wired are referenced on sheet AO. These smoke and CO detectors have specific requirements. Please indicate the location of each Smoke and CO detector in compliance with R314 and R315 of the 2015 IRC, including any state amendments on the plans. Response. See Smoke Detector Requirement Notes Sheet A2, Updated plans showing locations, Sheet A2 & A3. 3. It appears that each door has been labeled with a number for identification. A door schedule has not been provided on the plans. Please provide a door schedule on the plans that identifies size and safety features if applicable. Response: See Door Schedule, Sheet AO.1 4. The windows on the plans do not include any indicating factors. Please include on the plans individual window sizes, egress compliance, and any applicable safety features in accordance with section R308 of the 2015 IRC. Response: See Window Schedule, Sheet A0.1. S. Local exhaust fans are required in accordance with R1507.4 Please indicate on the plans the location and CFM rating of each individual exhaust fan in accordance with R1507.4. Response. See I st floor & 2 nd Floor HRV plans, sheet A0.1. Local exhaust in bathrooms to have "boost" feature. 6. Whole house ventilation is required per R1507.3. Please indicate on the plans the location and CFM rating of the selected method of ventilation in accordance with R1507.3 and any applicable state amendments. Response: See Ist floor & 2 nd Floor HRV plans, sheet A0.1. Local exhaust in bathrooms to have "boost" feature. 7. Appliance impact protection is required per M1307.3.1. Please indicate on the plans the means of impact protection for the hot water tank and furnace. 2 0 [S 16 hl I BLD20170615 Laughtland Residence 6 IJ I L 0 17/13/17 � 926 Walnut Street BALANCE Response. See bollard location in front of HIN tank, Sheet A2. End of Revision 01 addressing Building & Planning Comments. Attachments: Revised Architectural drawings Revised Civil Drawings Civil Comment response Stormwater Covenant Drainage report Right -of Way Construction Permit Application Side Sewer Permit Application 3