July 12, 2017
Jeff Oaklief
2124 V Ave
Seattle, WA 98121
Subject: Proposed Thai By Day, 182 Sunset Ave South, Edmonds
Dear Mr. Oaklief:
Environmental Health Division
RECEIVED
e
JUL -'!- "'. 2017
UEVELOPMENT SERVICES
COUNTER
Your plans have been reviewed with the Rules and Regulations of the State Board of Health, and with the policies
of the Snohomish Health District. With the' addition of the following conditions, the plans are approved.
1. The conditional approval of the plans for Thai By Day was based upon the plans submitted June 19,
2017, and the menu and HACCP submitted May 1, 2017. Any changes to these items will void this
approval.
2. The Health District operating permit application process must be completed prior to opening for business.
This facility will be classified as a high risk food establishment with 51-150 seats.
3. Three -compartment sinks must be NSF or equivalent listed with rounded corners and integral drainboards at
both ends. The basins of the three -compartment sink must be large enough to fit the largest item needing to
be washed.
4. An indirect waste drain (an air gap) is required for the food preparation sinks, sanitizer basin of the three -
compartment sink, mechanical dishwasher, ice machine, beer t2p line drain pan, woks, walk-in refrigeration,
and any equipment in which food is placed. Please note that a direct drain to a grease trap is not considered
an indirect drain even if the grease trap is indirectly drained.
5. A reduced pressure backflow prevention device is required at the end of the copper water pipe serving the
pop dispensing system prior to the carbonation device. No copper or brass pipe/fittings or other potentially
corrodible material is allowed after the reduced pressure backflow prevention device.
6. Each food preparation sink must be NSF or equivalent listed with at least one integral drainboard.
7. A horizontal separation of at least 16 inches or a pony wall, from the floor to at least 16 inches above the sink
basin, is required between the raw meat/poultry/seafood preparation sink and ready to eat food preparation
and storage areas.
8. A horizontal separation of at least 16 inches or a pony wall, from the floor to at least 16 inches above the sink
basin, is required between the raw meat/poultry/seafood preparation sink and the ready to eat food
preparation sink. The only acceptable option to the pony wall, other than the 16 inch horizontal separation, is
the use of a partition of at least 1 % inch in thickness (similar to the partitions in restroom stalls) from the floor
to at least 16 inches above the sink basin of a material that is waterproof.
9. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required between the
handwash sink and all food preparation areas.
10. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required in the prep
area between the handwash sink and the food preparation sink.
11. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required in the prep
area between the handwash sink and the three compartment sink.
12. A horizontal separation of at least 16 inches is required in the kitchen between the handwash sink and the
adjacent shelving.
13. A horizontal separation of at least 16 inches or a vertical partition 16 inches in height is required at the front
bar between the ice bin and the dump sink.
14. When splashguards (partitions and/or walls) are provided on both sides of a handwash sink the distance
between the splashguards must be at least 18 inches apart (shoulder width) to allow proper access to the
handwash sink.
15. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks and at the
same time provide hot water to all handwash sinks. Hot water must be available to all handwash sinks within
15 seconds. The hot water for the facility must not be used, at any plumbing fixture, for a minimum of 6 hours
prior to the preoperational inspection. This is required so that proper testing of the 15-second time
requirement for hot water availability can be completed.
3020 Rucker Avenue, Suite 104 0 Everett, WA 98201-3900 0 tel: 425.339.5250 0 fax: 425.339.5254
16. All food service equipment, both new and used, must be listed by the National Sanitation Foundation (NSF) or
equivalent for its intended use. Used and new refrigeration must be capable of holding food at temperature of
41'F or below.
17. Used equipment is subject to onsite inspection to determine acceptability for use in the proposed food service
establishment. Used equipment must be clean, in proper operating condition, and in good repair. Used
refrigeration must be capable of holding at a temperature of 41'F or below.
18. Extra wall protection is required on walls behind all sinks, including restroom handwash sinks, and food
preparation counters and tables. Sinks in corners must also have wall protection on the side walls. A 16-inch
high backsplash of plastic laminate, fiberglass -reinforced plastic or equal is acceptable. A backsplash higher
than 16 inches is required on the wall behind counter top equipment taller than 16 inches. Floor to ceiling
protection is required on the wall behind dishwashers. Wall protection behind rnop sinks must cover the entire
splash zone. Plastic coated hardboard is not acceptable.
19. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be
surfaced with a durable, nonabsorbent, easily cleanable material, Expansion joints, seams, saw cuts and the
like in concrete floors in all areas, including customer seating areas, must be filled and sealed so as to
provide a smooth and cleanable surface.
20. The ceiling above the food preparation areas must be non -perforated, nonabsorbent, smooth and easily
cleanable.
21. Cabinet shelving must be nonabsorbent, smooth and easily cleanable. (Self stick vinyl or other type surfaces
are not acceptable.)
22. All light fixtures in food preparation and storage areas must be provided with covers and shatterproof bulbs.
Hot hold unit heat lamps must be provided with shatterproof bulbs.
23. Plumbing must meet state and local codes.
24. It cannot be determined from the floor plan or information submitted whether or not a chemical dispensing
system will be installed at the mop sink. Please note that the use of screw -on type 'wye' adaptors at the mop
sink faucet for use with chemical dispensing systems is prohibited. Additionally chemical dispensers cannot
be connected to the mop sink faucet. The chemical dispenser must have a separate water connection. A
I sidekick' adaptor at the mop sink faucet is acceptable.
25. The ventilation system shall be installed and operated to meet applicable building, mechanical, and fire codes.
26. It is unclear as to the amount of dry storage area that will be provided. A dry storage area of sufficient size
must be provided. The amount of dry storage area must be determined by one of the following methods and
will be verified for amount at the preoperational inspection- a) a floor space (and wall shelo area equivalent to
25% of all the kitchen space, or b) one square foot of spa�e per customer seat.
A preoperational inspection is required prior to operating permit issuance and approval to open for
business. At the time of inspection the construction of the food service establishment must be complete and all
equipment must be in place and in proper operating condition. Incomplete construction or equipment operation
will result in a $180.00 re -inspection fee. Contact the Food Program office a minimum of one week in
advance to schedule an appointment for the preoperational inspection. The preoperational inspection will
ensure compliance with the Rules and Requlations of the State Board of Health for Food Service Sanitation.
Changes or additions to the approved plans or equipment require pre -approval from the Snohomish Health
District prior to implementation of the changes.
Please contact me if you have any questions. My office number is 425.339.8742 and my email address is
ehaqedornC@snohd.orq.
Sinqerely,-
ElaiKe Hagedorh, RS
Environmental Health Specialist
Food Establishment Plan Review
EH/kdc
Enclosure: Annual Food Establishment Permit Application, Fee Schedule
cc: City of Edmonds Building Department
WA State Liquor Control Board
Retta Taffesse, RS, Environmental Health Specialist