July 19, 2017
Mr. Ken Marquardt
Ram Jack West
850 Bethel Drive
Eugene, Oregon 97402
4001 Main Street, Suite 305
Vancouver WA, 98663
P: 360.566.7343
Re: Special Inspection — 560 Homeland Drive, Edmonds, Washington
Permit No.: BLD2017-0792
Dear Ken -
I have performed the special inspection of the installation of the push piers per ICC ESR-1854 for
the above- refe re nced project.
Helical Anchor - Installation
The helical anchor used for installation was a 2 7/8" diameter pipe with a 10" diameter helix
configuration. The installation was performed by Ram Jack West, certified installers for Ram Jack
products using a 2.5K drive head.
The maximum axial load requirement for this project is 9,000 lbs working load (18,000 lbs
ultimate). The anchors were driven to depths of 3'-6" — 8'feet with a minimum installation
pressure of 2,800 psi. This results in an ultimate axial capacity of 23,335 lbs, exceeding the
required ultimate load per the design documents.
Summary
Based on my special inspection and structural observation, the helical anchors were installed
according to the engineering design load requirements and according to ESR-1854.
Please give our office a call if you have any questions or need further assistance.
Regards,
Daniel Stark, P.E.
Stark Foundations, Inc.
Attachments: Drive Log
Helical Driver Torque Chart
IE(PMES : JULY 13, 2018 1
Page 1 of 3
5� L _a-'ffLMM.JJ&C1C
Foreman: Ken Doll CreW: Ken, Kenny Start Date:
HELICAL PIER DRIVE LOG
ADDRESS: 560 Homeland Drive
OWNER: Susan Wainer K Drive Head
JOB # 017-170
Special Inspection Engineer:
LU
Ln
LU
U)
a-
Ln
0.
LU
V)
0.
LU
V)
LU
U)
F-
LU
Ln
M
LU
V)
45
Dealer :
Ram Jack Systems Distribution, LLC
13655 County Road 1570
Ada, OK 74820
Hydraulic Motor
Model :
Displacement (in 3)
Gear Drive:
Model
Ratio
Tnrnup Chart
Sauer Danfoss 151-7257
19.32
Fairl'ield S07A26604
4.1
HELICAL DRIVER TORQUE CHART
2.5K Driver
9) RAMJACK
Torque Equation :
T= (Pressure*displaceme !� Gear Ratio*77 *77gear
247T motor
where Pressure hydraulic pressure (psi)
Displacement hydraulic motor displacement (in 2)
17 motor motor efficiency
I gear gear drive effildency
Pres sure (psi)
1 5001
750
1 1,000
1 1,250
1 1,500
1 1,750
1 2,000
1 2,250
1 2,500
1 2,750
3,00
Torque (ft-lbs)
1 4631
6951
9271
1,158
1 1,390
1 1,622
1 1,853
1 2,085
1 2,317
1 2,548
1
-TE :
Ultimate Car)acitv 1,2,3
The torque can also be calculated at ayiy hydraulic pressure by multiplying the pressure b-y the psiliorque-factor.for this
helical driver which is 0.926.
2 3/8" dia. shaft (K, = 10)
4,633
6,950
1 - 9,-266
11,583
13,899 16,216
18,532
20,849
23,165
25,482
27,798
2 7/8" dia. shaft (K, = 9)
4,170
6,255
1 8,340
10,424
12,509
1 14,594
16,679
18,764
20,849
22,934
25,019
*NOTE: 1) Ultimate Capacitv(Qj = Installation Torque (T) x Torque Correlation Factor(Kj.
2) Capacities shown in table assurnes the pile isfully braced and has no eccentric loading.
3) A safety factor of2 should be qpplied to the ultimate capacity to obtain the working load capacity
CD