20170726155044.pdfRAM Engineering Jennifer Lambert City of Edmonds Planning Division 1215 Ih Avenue North Edmonds, WA 98020 RE: Kirschner SFR- 753 Bell St Plan Check BLD20161610 2 nd Review Comment Response RAM Job No. 16-020 Ms. Lambert: RESUB JUL 2 '1 2017 13UILDING DEpARTMENT CITY OF EDMONDS June 19, 2017 This letter outlines the revisions and corrections made per the City's review comment memo dated June 14, 2017. Below is a list of the comment response documents addressing the comments and requests: GENERAL 1) Submit ROW Ecum, Applic-111m, form Response: See attached ROW permit application. 2) SubmitSide Scwcr Permil Api)licatiml form Response: See attached Side Sewer permit application. 3) A Stormwater Covenant is required to be recorded against the property based on the proposed stonilwater facilities for the project. Please complete the covenant, including notarization and any required exhibits and submit to the city. The document must be complete, but will not be recorded prior to permit issuance. Prior to construction final location of facilities are to be verified (by field inspection and asbuilt) and then the covenant will be recorded. Response: See attached Stormwater Covenant. SITE DEVELOPMENT PLAN 1) The note"the sewer line must be cut and capped a minimum of 20' from the existing and/or proposed foundation, whichever is closest to the sewer stub" was not found. Please provide - Response: Note added sheet 1 as requested. 2) The sewer cleanout at the property line will need a 12" cast iron lamphole cover with 1/2" hexbolts. Update the note accordingly Response: Okay, cost iron lamphole cover revised as noted. 3) The sewer cleinout at the house does not need a 12" cast iron laillphole cover with 1/2" hexbolts. Response: Okay, cast iron lamphole cover removedfrom onsite (house) SSCOs. 4) The sewer seii-ice connection between the house and the cleatiout at the property line is currently shown at 24%. Please reduce the sewer slope to 20% or add a note that the sewer line -,vill need to be anchored. Anchors need to be designed by a civil engineer and detailed oil the plans. Response: Side sewer depth at house lowered 18" to reduce slope below 20% (18.3916). RAM Engineering 165311311 Ave W, Suite A108 Lynnwood WA 98037 (425) 678-6960 RAM engineeringi nc.corn Kirschner SFR- 753 Bell St Plan Check BLD20161610 2nd Review Comment Response RAMJob No. 16-020 GENERAL NOTES 1) There are text conflicts around general notes 36 and 37. Response: Text conflicts removed. TESC PLAN 1) The cillout referencing the filter fabric fence references the detail on "this sliect". Please revise the reference to Sheet DT-01 - Response: Filterfabric reference revised to Sheet DT-01 as requested. Page 2 of 2 If there are any questions regarding the items above or the contents of the revised drawings, please contact me at your earliest convenience; I can be reached at (425)678-6960 or RobL@RAMengineeringinc.com. We sincerely appreciate your time and assistance. Thank you, Rob Long, PE Principal "M Engineering 16531 131h Ave W, Suite A108 Lynnwood WA 98037 (425) 678-6960 RAM engineeringi nc.com