Loading...
20170727111648.pdfCONSTRUCTION IfT OF WASHINGTON, LLC May 30, 2017 City of Edmonds Attn: Building Official Edmonds, WA Re: Willowdale Townhomes 20732 76" Ave. Edmonds, WA Contractor: Pacific Ridge Homes Permit #: BLD2016-0562 Final inspection report for Building Enclosure Elements for Buflding A Diane Glenn All inspections performed at the project were based on the builder's plans and specifications, product manufacturer's specifications, and good industry standards and practice. All references made are to the plans and specifications developed specifically for the project. Course of construction inspections were performed of the building enclosure for the purpose of quality application of material to meet city approved plans and specifications. Site inspection reports were submitted during course of construction and a full report and photos was submitted to owner. Inspections comply with requirements of RCW64-55. All following areas were inspected and observed to be completed with no outstanding correction items. The window water penetration resistance testing was perfon-ned per RCW 64.55.050 on a sample of windows at the project and the results were a pass. Window flashing and installation; sliding door flashing and installation; weather barrier; siding flashing and trim caulking; deck to wall attachment flashing; and exterior penetrations. Submitted by: Diane Glenn Construction Consultants of Washington, LLC Building Enclosure inspector Office (425)709-6100 Cell (425)351-0940 40 Lake Bellevue, Suite 100, Bellevue, WA 98005 CONSTRUCT N A./i OF WASHINGTON, LLC May 4, 2017 City of Edmonds Attn: Building Official Edmonds, WA Re: Willowdale Townhomes 20736 76", Ave. Edmonds, WA Contractor: Pacific Ridge Homes Permit #: BLD2016-0563 Final inspection report for Building, Enclosure Elements for Building B Diane Glenn All inspections performed at the project were based on the builder's plans and specifications, product manufacturer's specifications, and good industry standards and practice. All references made are to the plans and specifications developed specifically for the project. Course of construction inspections were performed of the building enclosure for the purpose of quality application of material to meet city approved plans and specifications. Site inspection reports were submitted during course of construction and a full report and photos was submitted to owner. Inspections comply with requirements of RCW64-55. All following areas were inspected and observed to be completed with no outstanding correction items. The window water penetration resistance testing was performed per RCW 64.55.050 on a sample of windows at the project and the results were a pass. Window flashing and installation; sliding door flashing and installation; weather barrier; siding flashing and trim caulking; deck to wall attachment flashing; and exterior penetrations. Submitted by: Diane Glenn Construction Consultants of Washington, LLC Building Enclosure inspector Office (425)709-6100 Cell (4125)351-0940 40 Lake Bellevue, Suite 100, Bellevue, WA 98005 CONSTRUCTION Diane Glenn /17 OF WASHINGTON, LLC May 30, 2017 City of Edmonds Attn: Building Official Edmonds, WA Re: Willowdale Townhomes 20730 76"' Ave. W Edmonds, WA Contractor: Pacific Ridge Homes Permit #: BLD2016-0561 Final inspection report for Building Enclosure Elements for Building C All inspections performed at the project were based on the builder's plans and specifications, product manufacturer's specifications, and good industry standards and practice. All references made are to the plans and specifications developed specifically for the project. Course of construction inspections were performed of the building enclosure for the purpose of quality application of material to meet city approved plans and specifications. Site inspection reports were submitted during course of construction and a full report and photos was submitted to owner. Inspections comply with requirements of RCW64-55. All following areas were inspected and observed to be completed with no outstanding correction items. The window water penetration resistance testing was performed per RCW 64.55.050 on a sample of windows at the project and the results were a pass. Window flashing and installation; sliding door flashing and installation; weather barrier; siding flashing and trim caulking; deck to wall attachment flashing; and exterior penetrations. Submitted by: Diane Glenn Construction Consultants of Washington, LLC Building Enclosure inspector Office (425)709-6100 Cell (425)351-0940 40 Lake Bellevue, Suite 100, Bellevue, WA 98005