Loading...
20170920143934.pdfThe V,a 1 0 P Driftmier Architects, P.S. September 18, 2017 City of Edmonds Building Division 17544 Midvale Avenue North Shoreline, WA 98133 Re: Permit Number: BLD2017-1073 Kuzma's Fish Market 1215 th Ave N Edmonds, WA 98020 Mr. Chuck Miller, 7983 Leary Way NE Redmond, WA 98052 Phone: (425) 881-7506 Fax: (425) 881-7306 RESUB s1p 18 2017 IBUILI)ING DEPARTMENI CI-f y OF F-DtAONL)S This letter responds to the Plan Review Comments dated September 7, 2017 that we received on the proposed commercial remodel to building at 21104 70th Ave W. The appropriate revisions have been made to the drawings as noted in our responses below, which follow the numbering of the Plan Review Comments. Response o Plan Review Comments dated 9/7/117: Engineering Development Guide 1) HEALTH DEPARTMENT The business owner will be submitting documentation to the Health Department. 2) CODE SUMMARY a. Proposed Area information in detail 3/A1.0 and detail 8/A1.0 have been updated to reflect areas from inside face of walls. b. Occupant Load The areas included on A1.0 and the lighting form have been updated so that the Sales Area includes the service counter and the food prep counter to the west of the sales counter. 3) PLANS a. Wall Type Callouts Detail 1/A2.1 has been updated and the new walls have tags that designate their construction. Please note that the proposed walls for the new office were deleted. The owner determined they did not need an office so this space has been designated as kitchen area. Kuzma's Fish Market Permit Response Letter September 17, 2017 Page 2 b. Water Heater for Lavatory A note has been added to 3/A1.0 and to F5.0 that an on -demand hot water heater is to be installed for the toilet room lavatory. c. Drinking Fountain The occupant load for the space is calculated to be 29. Per the Washington State amendments to the IBC, spaces with an occupant load of less than 30 are not required to have drinking fountains. d. Sales Counter A note wall added to 1/A1.0: "Service counter to have 36" max height counter with a minimum width of 36". Finish plan designer has confirmed that the ordered counter is 34" high. 4) MAX INTERIORWATTS The lighting form has been updated to calculate areas from inside face of walls. The Sales Area was expanded to include the sales counter and the food prep area. 5) INTERIOR DISPLAYLIGHTING a. Track Lighting The lighting form has been updated and lists the track lighting as using 50 watts per linear foot. Additionally, all track lighting has been moved from the typical lighting to Interior Display Lighting. b. Light Fixture Count The Lighting Plan on F8.0 and the fixture schedule have been updated/altered. Lighting was changed to reduce costs. The lighting form has been updated to correctly reflect the fixture counts shown on F8.0. ADDITIONAL CHANGES 1) F2.0/F3.0—Fixture/item Plans a. Replace steam kettle with a stock pot range. b. Remove air doors over garage doors. 2) F5.0 — Plumbing Plan a. Added stock pot range to replace the steam kettle. Please contact me with any further questions, comments or corrections. Sincerely, Kuzma's Fish Market Permit Response Letter September 17, 2017 Page 3 Lee Driftmier, AIA, Principal Architect The Driftmier Architects, P.S. Attachments: Updated drawings sheets, Updated lighting form