STANDBY GENERATORS
8&11 kW
AIR-COOLED GENERATOR SETS
Standby Power Rating
Model 006703-0 (Aluminum - Dark Gray) - 8 kW 60 Hz
Model 006442-1 (Aluminum - Dark Gray) - 11 kW 60 Hz
INCLUDES
• PrecisionPower" Electrical Technology
• Two Line LCID Multilingual Digital Controller
(English/Spanish/French/Portuguese)
• Electronic Governor
• External Main Circuit Breaker, System Status
& Maintenance Interval LED Indicators
• Flexible Fuel Line Connector
• GFCI Duplex Outlet
• WhisperCheckT' Exercise
FEATURES
0 INNOVATIVE DESIGN &
PROTOTYPE TESTING are key
components of our success in "IMPROVING
POWER BY DESIGN." But it doesn't stop
there. Total commitment to component
testing, reliability testing, environmental
testing, destruction and life testing, plus
testing to applicable CSA, NEMA, EGSA,
and other standards, allows you to choose
Honeywell generators with the confidence
that these systems will provide superior
performance.
0 TEST CRITERIA
• PROTOTYPE TESTED
• SYSTEM TORSIONAL TESTED
• NEMA MG11-22 EVALUATION
• MOTOR STARTING ABILITY
Honeywell
RECEIVED
SEP 19 2017
BUILDING
I Mobile V1
• Mobile Link" Cellular Monitoring System* \Z�
• Composite Mounting Pad 40us
• Aluminum Enclosure LISTEO
• Base Fascia
• Natural Gas or LP Gas Operation
• 5 Year Comprehensive Warranty
• Capability to be installed within 18" (457 mm) of a building"
Download the free App at 101111 Q=
Only if located away from doors, windows and fresh air intakes, and unless
otherwise directed by local codes.
0 Precision Power— ELECTRICAL
TECHNOLOGY Superior harmonics and
sine wave form produce less than 5% Total
Harmonic Distortion for utility quality power.
This allows confident operation of sensitive
electronic equipment and micro -chip based
appliances, such as variable speed HVAC-
0 SOLID-STATE, FREQUENCY
COMPENSATED VOLTAGE
REGULATION This state-of-the-art power
maximizing regulation system is standard
on all Honeywell models. It provides
optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR
STARTING CAPABILITY by electronically
torque -matching the surge loads to the
engine. Digital voltage regulation at +/_ 1
0 SINGLE SOURCE SERVICE
RESPONSE from our extensive dealer
network provides parts and service know-
how for the entire unit, from the engine to
the smallest electronic component.
0 Honeywell TRANSFER SWITCHES
The Honeywell generator line includes its
own transfer systems and controls for total
system compatibility.
0 Mobile Link Cellular Monitoring
System - Mobile Link is a cellular remote
monitoring system that lets you check
your generator's status even when you are
away using your computer, tablet or smart
phone. With Mobile Link, you will always
know exactly what your generator is doing
when you are on the go. To learn more go to
www.mobilelinkgen.com.
P)L D c'00*0 I I � Q H
8&11 kW
AIR-COOLED GENERATOR SETS
ENGINE
A - -
Generac OHVIO design
Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings
help the engine run cooler. reducing oil consumption resulting in longer engine life.
"Spiny-lok" cast iron cylinder walls
Rigid construction and added durability provide long engine life.
Electronic ignition/spark advance
These features combine to assure smooth, quick starting every time.
Full pressure lubrication system
Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life.
Now featuring up to a 2 year/200 hour oil change interval.
Low oil pressure shutdown system
Shutdown protection prevents catastrophic engine damage due to low oil.
High temperature shutdown
Prevents damage due to overheating.
GENERATOR
Revolving field Allows for smaller, light weight unit that operates 25% more efficiently than a revolving armature generator
Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
Displaced phase excitation Maximizes motor starting capability.
Automatic voltage regulation Regulates the output voltage to ±1% prevents damaging voltage spikes.
UL 2200 listed For your safety.
TRANSFER SWITCH
Sold separately
SYNCym 2.0 CONTROLS
Auto/Manual/Off illuminated buttons
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
Two-line LCD multilingual display
Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences.
Sealed, raised buttons
Smooth, weath er- resistant user interface for programming and operations.
Utility voltage sensing
Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up, of standard voltage.
Generator voltage sensing
Constantly monitors generator voltage to ensure the cleanest power delivered to the home.
Utility interrupt delay
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer
Engine warm-up
Ensures engine is ready to assume the load, setpoint approximately 5 seconds.
Engine cool -down
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Programmable exerciser
Operates engine to prevent oil seal drying and damage between power outages by running the generator for 12
minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility
Smart battery charger
and lower fuel costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Electronic governor
Maintains constant 60 Hz frequency.
UNIT
Aluminum weather protective enclosure Provides protection against mother nature and can withstand winds up to 150 mph. Hinged key locking roof panel
for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy
paint for added durability.
Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building.*
INSTALLATION SYSTEM
1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe.
Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities.
2 www.honeyweIlgenerators.com
GENERATOR
Model 006703-0 (8 kW) Model 006442-1 (11 I(W)
Rated Maximum Conflnuous Power Capacity �(LP)
8,000 Watts* 11,000 Watts*
Rated Maximum Continuous Power Capacity (NG)
7,000 Watts* 10,000 Watts*
Rated Voltage
240 240
Rated Maximum Continuous Load Current — 240 V (LP/NG)
33.3/29.16 45.8/41.7
Total Harmonic Distortion
Less than 5% Less than 5%
Main Line Circuit Breaker
50 Amp 50 Amp
Phase
1 1
2
Number of Rotor Poles
2
60 Hz 60 Hz
Rated AC Frequency
1.0
Power Factor
1.0
Battery Requirement (not included)
Group 26R, 12 Volts and 525 CCA Minimum
Unit Weight (lb/kg)
421/190.9 373/169.2
Dimensions (L x W x H) in/mm
48 x 25 x 29/1218 x 638 x 732
Sound output in dB(A) at 23 ft (7 m) with generator operating at
63
normal load**
66
Sound output in dB(A) at 23 ft (7 m) with generator in WhisperCheek'"
57
low speed exercise modo**
60
04kiLmai�� —
Type of Engine
— —
GENERAC OHVI GENERAC OHVI
Number of Cylinders
1 2
410 cc 530 cc
Displacement
Cylinder Block
Aluminum w/ Cast Iron Sleeve Aluminum w/ Cast Iron Sleeve
Valve Arrangement
Overhead Valve Overhead Valve
Ignition System
Solid-state w/ Magneto Solid-state w/ Magneto
Governor System
Electronic Electronic
Compression Ratio
9.5:1 9.5:1
Starter
12 Vdc 12 Vdc
Oil Capacity Including Filter
Approx. 1.5 qV1.4 L Approx. 1.7 qt/1.6 L
Operating rpm
3,600 3,600
Fuel Consumption
Natural Gas ftl/hr (m3ft)
112 Load
78 (2.21) 124 (3.51)
Full Load
121 (3.43) 195 (5.52)
Liquid Propane ftl/hr (gal/hr) [Vhrl
1/2 Load
31.6 (0.87) [3.291 42.8 (1.18) [4.45]
Full Load
5 .6 (1.42) [5.37] 70 (1.92) [7.281
1
Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet - 3.5-7" water column (7-13 mm mercury) for natural gas, 10-12" water column
(19-22 mm mercury) for LIP gas. For Btu content, multiply ftl/hr x 2500 (LP) or fta/hr x 1000 (NG). For Megajoule content, multiply ml/hr x 93.15 (LP) or m3/hrx 37.26
(NG),
millikill.toll6� E
2-Line Plain Text Multilingual LCD Display
—
Simple user interface for ease of operation.
Mode Buttons: Auto
Automatic Start on Utility failure. 7 day exerciser.
Manual
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Off
Stops unit. Power is removed- Control and charger still operate.
Ready to Run/Maintenance Messages
Standard
Engine Run Hours Indication
Programmable start delay between 2-1500 seconds
Standard
Standard (programmable by dealer only)
Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting)
From 140-171 V/ 190-216 V
Standard
Future Set Capable Exerciser/Exercise Set Error Warning
Run/Aiatm/Mainlenance Logs
50 Events Each
Engine Start Sequence
Cyclic cranking: 16 sec on. 7 rest (90 sec maximurn duration).
Starter Lock -out
Starter cannot re-engage until 5 sec after engine has stopped.
Smaft Battery Charger
Standard
Charger Fault/Missing AC Warning
Standard
Low Baftery/Banery Problem Protection and Battery Condition Indication
Standard
Automatic Voltage Regulation with Over and Under Voltage Protection
Standard
Uiider-Ffequency/Oveiload/Stepper Overcurrent Protection
Standard
Safety Fused/Fuse Problem Protection
Standard
Automatic Low Oil Pressure/High Oil Terripetature Shutdown
Standard
Overcrank/Overspeed ((p 72 Hz)/fpm Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Intemal Faull,Incofrect Wiring Protection
Standard
Common External Fault Capability
Standard
Field Upgradable Firmware
Standard
—Sound levels ale taken from trio liond of the generator Sound levers taken from other sides or the, generate( may be higher depending on installation parameters. Rating definitions - Standby. Applic able for supplying
emeigency povars for the duration of the lAddy po-Ati outage. No overload capability is available lot this rating (AM ratings in accordance vvilh BS5514. IS03046 and DIN65271) * Maximum wattage and current are sibiect to
and limited by such factors as fuel Blutmeg3rOule content. ambient temperature, altitude. engine power
and condition. etc Ma)umum Power decreases aboull 3.5 percent for each 1,000 feet (304.8 meters) above sea level: and
also will decrease about I percent for each 6 T (10 'F) above 16 T (60 T).
AVAILABLE ACCESSORIES
Model # Product
Description
26R Wet Cell
Every standby generator requires a battery to start the system. The recommended 26R
005819-0 Battery
wet cell battery is for use with all air-cooled standby product.
If the temperature regularly falls below 32 oF (0 oC), install a cold weather kit to maintain
006212-0 Cold Weather Kit
optimal battery and oil temperatures. Kit consists of a battery warmer and oil filter heater
with built-in thermostats.
005621-0 Auxiliary Transfer The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large
Switch Contact Kit electrical load you may not need.
If the generator enclosure is scratched or damaged, it is important to touch-up the paint
006160-0
Paint Kit
to protect from future corrosion. The paint kit includes the necessary paint to properly
maintain or touch-up a generator enclosure.
006482-0 (8 kW)
Scheduled
Scheduled maintenance kits provide all the hardware necessary to perform complete
006483-0 (11 kW)
Maintenance Kit
routine maintenance on a Honeywell automatic standby generator.
Smart Management
Manage large loads by utilizing up to 8 individual Smart Management modules. These
006874-0
Module (50 Amps)
devices are installed directly in line with existing appliance wiring for easy installation.
DIMENSIONS & UPCS
731
128
637.6 mm
[25.3 in]
LEFT SIDE VIEW
Generac Power Systems, Inc.
S45 W29290 Hwy. 59
Waukesha, WI 53187
Tel: 1-855-GEN-INFO
honeyweligenerators.com
FRONT VIEW
OK8460-C
May 2015
0 Generac Power Systems, Inc All rights reserved.
Specifications subject to change without notice.
The Honeywell Trademark is used under
license from Honeywell International Inc.
Honeywell International Inc makes no representallon
or warranties with respect to this product.
Model UPC
006703-0 696471067033
006442-1 696471064421
Hon,QXMALfiMJJ
quj wwx,—
This product is manufactured by Generac Power Systems, Inc