Loading...
2017-1103 Mostad Alteration.pdfCity of Edmonds OV EDAI 0 PLAN REVIEW COMMENTS . ..... BUILDING DIVISION (425) 771-0220 DATE: September 6, 2017 TO: Sam Mostad smostad@yahoo.com FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2017-1103 Project Address: 7001 Ballinger Way Scope: Alteration / Single Family Dwelling, — R-3/U occupancy group — V-B construction— mechanical and plumbing included Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicatin2 where the 'clouded' or otherwise hi2hli2hted chan2es can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. During the cursory review of the submitted building plans, several items were found to be insufficient or more clarification is needed prior to plan approval. General: 1. The architectural plans were submitted on 11"xl7" paper in a 1/8" scale. The City of Edmonds requires 1/4" scale or larger. Please provide plans that 1/4" =1' or larger. 2. R3015.3, Carbon Monoxide detectors are required to be installed and interconnected outside each sleeping area and each level of the home. Please indicate on the plans. 3. Local exhaust shall be provided in each kitchen, bathroom, water closet, laundry room, spa, and any other room where water vapor or cooking odors are produced. It appears that some of the required exhaust fans are indicated. Please indicate on the plans the location and CFM rating of required local exhaust fans in compliance with 2015 IRC RI 507.4 4. Please indicate locations of bathroom fixtures on the plans. This is required for review of any glazing located in hazardous locations. 5. It appears that the window sizes have been identified on the plans. More information is needed. Please identify the size, style of operation, if its intended to be used as an emergency egress, or if located in a hazardous location with R308 indicate as being " safety glazed" , and U value of proposed windows and doors on the plans on the plans. 6. Please provide stair details, including the rise and run, handrail locations and height, guardrail details including height, and picket spacing on the plans 7. Please number all pages of the plans for reference. This plan review has not been completed, additional comments may be generated upon review of the resubmitted documents. Please let me know if I can be of any additional assistance. Eric Carter Page 2 of 3 Page 3 of 3