2017-1175 Thorson Addition (Tutmarc Arch).pdfCity of Edmonds OV EDAI 0 PLAN REVIEW COMMENTS . ..... BUILDING DIVISION (425) 771-0220 DATE: October 2 d 2017 TO: Greg Andrews Tutmarc Architects TUTGREG@MSN.COM FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2017-1175 Project Address: 18604 Soundview DR. Scope: Addition, VB construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the 'clouded' or otherwise hi2hlighted chani!es can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: General: Structural and lateral calculations from Terry Baldwin PE for the addition were provided with the submittal. Any plans and or details designed by the Engineer of Record must be reviewed for compliance and stamped as so. Please provide two sets of plans reviewed and stamped by the E.O.R. 2. This addition is excess of 500 square feet of conditioned floor space. Which now requires that a whole house ventilation system is to be installed in accordance with Washington state amended version of IRC M 1507.3. If an existing whole house ventilation system is currently installed and in compliance with M 1507.3 or a new system is to be installed please note on the plans. 3. This addition is in excess of 500 square feet of conditioned floor space. The 2015 Washington State Energy code requires additions of 500 square feet or greater to comply with the prescriptive requirements of table R402. 1.1 plus an additional 1.5 credits from table 406.2. Please indicate these requirements and additional elected credits on the plans A3. 1: 4. Cross section 3/A8.5 is indicated on the plans. Page A8.5 was not included with this submittal. Please submit 2 copies of page A8.5 or change the detail. A3.2: 5. Cross section I/A8.5 is indicated on the plans, page A8.5 was not included with this submittal. Please submit 2 copies of page A 8.5 or change the detail. A4. 1: FIX M A5: S2.2: 6. Cross section 4/A8.5 is indicated on the plans, page A8.5 was not included with this submittal. Please submit 2 copies of page A 8.5 or change the detail. 7. Cross section I/A8.5 is indicated on the plans, page A8.5 was not included with this submittal. Please submit 2 copies of page A 8.5 or change the detail. 8. Cross section 3/A5 indicates detail bugs 6, 7, 8, and 10/ A8.5. Page A8.5 was not included with this submittal. Please submit 2 copies of page A8.5 or change the detail. 9. The office/ Addition roof framing plan has a note specifying the "2x6 ledger fastened to existing rim joist w/ xxxxxx". Please clarify what "xxxxxx" is intended as on the plans. Page 2 of 3 Please let me know if I can be of any additional assistance. Eric Carter Page 3 of 3