2017-1276 Select SFR (NASH).pdfCity of Edmonds
OV EDAI 0
PLAN REVIEW COMMENTS
. ..... BUILDING DIVISION
(425) 771-0220
DATE: October 30, 2017
TO: Select Homes
Kayla Clark
kayla.clarkkoutlook.corn
FROM: Eric Carter, Plans Examiner
RE: Plan Check: BLD2017-1276
Project Address: 23932 104th AVE W.
Scope: New / Single Family Dwelling, — R-3/U occupancy group — V-B
construction— mechanical and plumbing included
Please be advised that the building plans for the above referenced project have been disapproved
for the purposes of obtaining a building permit. During a review of the plans by the Building
Division for compliance with the applicable building codes, it was found that the following
information, clarifications, or changes are needed. Reviews by other divisions, such as Planning,
Engineering, or Fire, may result in additional comments that require attention beyond the scope of
this letter. Items that recur on this list appear in italics.
A complete review cannot be performed until the revised plans/documents, including a
written response in itemized letter format indicatinz where the 'clouded' or otherwise
highlij!hted chani!es can be found on the revised plans, have been submitted to a Permit
Coordinator.
Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall.
Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays.
This building plan review cannot be completed until we receive the following items:
1wel
1. The exterior wall of the bonus room above the garage is labeled as a P 1 -6 shear wall
with MSTC48133 straps at each end of the walls. It is unclear to what the B3 straps will
attach to as the garage door header below is not directly below the upper wall and the
floor trusses are perpendicular to the wall as well. Please clarify how the upper walls
will transfer to the lower walls.
Please let me know if I can be of any additional assistance.
Eric Carter
Page 2 of 2