2017-1288 Newsome ADU.pdfCity of Edmonds OV EDAI 0 PLAN REVIEW COMMENTS . ..... BUILDING DIVISION (425) 771-0220 DATE: October 24, 2017 TO: Robert Newsome mewsome@comcast.net FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2017-1187 Project Address: 23730 104th AVE W Scope: ADU Addition / Single Family Dwelling, — R-3/U occupancy group — V-B construction— mechanical and plumbing included Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the 'clouded' or otherwise hi2hli2hted chan2es can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. During the cursory review of the submitted building plans, several items were found to be insufficient or more clarification is needed prior to plan approval. Site plan: 1. This plan will be reviewed under the 2015 Washington State Energy code. The plans reference 2012 WSEC. Please update the note on the plans. 2. The 2015 WSEC requires that these plans identify the prescriptive requirements of table R402.1.3 plus an additional 1.5 energy credits from table R406.2. Please reference elected energy credits on the plans. General: The primary residence and the proposed ADU must act as independent dwellings. Please indicate on the plans where the electrical panel, water shut off, gas service disconnect and heating appliances will be located for the proposed dwelling. These locations must be readily accessible to the dwelling they service without having to access through the adjacent dwelling. 4. In each unit, smoke alarms shall be installed in each sleeping room, outside of each separate sleeping area and in the immediate vicinity of the bedrooms, and on each level (including basements and habitable attics). All required smoke alarms shall be interconnected in such a manner that the actuation of one alarm will activate all alarms in both the primary dwelling unit and the accessory dwelling unit. Please indicate the locations of the smoke alarms on the plans. 5. Carbon Monoxide alarms are required to be installed one each level of the proposed ADU dwelling and within the immediate vicinity of each sleeping area. Please indicate the locations of the CO alarms on the plans. 6. Construction details or references to the S sheets are not indicated on the A pages of the plans. Furthermore; the Engineer of Record must review and stamp each page of the plans in which their work has been used or identified for compliance. Please have the Engineer of Record review the proposed A pages and stamp for compliance. 7. Local exhaust fans shall be installed in each kitchen, bathroom, water closet, laundry room, and any other room where water vapor or cooking odors are produced per the 2015 International Residential Code section M 15 07.4 Please indicate on the plans the location and CFM rating of each local exhaust fan in accordance with section M 1507.4. 8. Each new dwelling shall be equipped with a "whole house" ventilation system. Please indicate on the plans what method of whole house ventilation will be used in accordance with IRC M1507.3. 9. Emergency escape and reuse openings are required. Basements, habitable attics and every sleeping room shall not have less than one operable emergency escape and rescue opening. These openings must have not less than 5.7 square feet of net clear opening. These openings must have a minimum clear width of 20 inches and clear height of 24 inches. Window sill heights must not exceed 44 inches off the floor. Please indicted which openings will be used as the emergency escape opening on the plans. This plan review has not been completed, additional comments may be generated upon review of the resubmitted documents. Please let me know if I can be of any additional assistance. Eric Carter Page 2 of 3 Page 3 of 3