Loading...
2018-0010 Osborne ( HD2 ).pdfCity of Edmonds OV EDAI 0 PLAN REVIEW COMMENTS . ..... BUILDING DIVISION (425) 771-0220 DATE: February 7, 2018 TO: HD2 Architecture & Design Lisa Montalvo FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018-0010 Proj ect Address: 10 102 24 I't PL SW Scope: Interior Remodel/ Addition, VB construction. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, includint! a written response in itemized letter format indicating where the 'clouded' or otherwise hh!hlh!hted chanus can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: S 2.0: A 5/8"x5" Anchor bolt is specified as anchorage for the HDIJ2 for the W4 Shear Wall on the Main Level Framing/ Foundation plan. The Hold Down Schedule also notes to refer to manufactures installation instructions. The specified anchor does not appear to meet the minimum embedment or requirements as specified by Simpson. Please clarify which type and size of anchor bolt is to be use in accordance with manufactures installation instructions. Please let me know if I can be of any additional assistance. Eric Carter Page 2 of 2