2018-0368 Regent SFR.pdf - LEGACYOV EDAI 0 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: April 24, 2018 TO: Robin Michel Regent Construction FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018-0368 Project Address: 7235 Soundview Lane Scope: NEW SFR, VB construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, includini! a written response in itemized letter format indicatin2 where the 'clouded' or otherwise hh!hlh!hted chanus can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: A2: I The north elevation on page A1.2 and the north wall openings on page A2 do not appear to match. Please clarify and change on the plans. 2. The den/ guest room is considered a sleeping room and will require a smoke detector inside the room. Please indicate the required smoke detector on the plans. A3: 3. The west elevation as shown on page Al. I and the west wall openings on A3 do not appear to match. Please clarify and change on the plans. 4. The 60/40 sliding window above the soaker tub appears to be located in a "hazardous location" and will be required to be safety glazed. Please indicate the required safety glazing on the plans. A5: 5. The toilet room located within the master bath will require a local exhaust fan. Please indicate the fan on the plans. 6. 2x8 HF #2 floor joists 16" OC are indicated on the plans but do not coordinate with what is indicated on page S5. Please clarify and change on the plans. 7. 117/8" 2 10 series floor j oists 16" OC are indicated in the notes section of the plans for the second floor but do not coordinate with what is indicated on page S6. Please clarify and change on the plans. Please let me know if I can be of any additional assistance. Eric Carter Page 2 of 3 Page 3 of 3