Loading...
2018-0416 HO and CO Awning.pdfOV EDAI 0 St. I DATE: TO: FROM RE: City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 March 30, 2018 Luke Walker Lukew@rainier.com Eric Carter, Plans Examiner Plan Check: BLD2018-0416 Project Address: 508 Main Street Scope: Installation of new Canopy. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicatinz where the 'clouded' or otherwise highlij!hted chani!es can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 nd Floor of City Hall. Permit Center hours are M, T, THz, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: General: As noted in section 3105.3 of the 2015 International Building Code. Awnings and Canopies are required to be designed in compliance with Chapter 16 of the IBC. Please submit a design and calculations that comply with sections 1608 and 1609. This design must be completed and stamped by a Washington State licensed Engineer. 2. Awnings and canopies shall be provided with an approved covering that meets the fire propagation performance criteria of either test method I or 2 as appropriate of NFPA701 or has a flame spread index of not greater than 25 in accordance with ASTM E or UL723. Please add this information to the plans. This plan review is considered incomplete, additional comments may generated upon the second review. Please let me know if I can be of any additional assistance. Eric Carter Page 2 of 2