20180525071331.pdfMay 07, 2018 Attn: Chuck Miller City of Edmonds Building Division 1215 th Ave N i Edmonds, WA 98020 architecture - design I received the correction notice for project tMLD20171743' ated April 20, 2018. Below are the requested corrections and locations on the drawings where they can be found: 1. Project Valuation to be revised to 49,966. Refer to attached itemized estimate from the General Contractor. 2, See attached approval letter from Environmental Health Division of the Snohomish Health District based on the plans dated 3/20/18. 3. General Notes a. 1. Codes i. Note revised to "IBC". Refer to 01 Sheet. ii. "Residential" eliminated from notes. Refer to 01 Sheet. b. 6. Energy i. First note code reference revised to "IBC". Refer to 01 sheet. ii. Third note eliminated. Refer to 01 sheet. c. 7. Exit Signs — First note code reference revised to "1013". Refer to 01 sheet. d. 8. Stairs i. First note code reference revised to "1011.3". Refer to 01 sheet. ii. Second note code reference revised to "1014". Refer to 01 sheet. iii. Third note code reference revised to "1014". Refer to 01 sheet. e. 9. Insulation i. First note code reference revised to applicable sections found in the WSEC Commercial Provisions. Refer to 01 sheet. ii. Second note eliminated. Refer to 01 sheet. iii. Fourth note revised to include information found in WSEC Table C402.1.3. Refer to 01 sheet. 4. Note added indicating required directional signage at inaccessible ramp to nearest accessible route. Refer to 02 sheet. S. Main Floor Plan a. Guardrail Height revised to 42" at stairs/landing to door'03'. Refer to sheet Al.l. b. Private Lounge door proposed to be removed to provide 32" clear framed opening. Refer to sheet Al. I. c. Safety glazing not required at existing window. Window is clear of the 24" arc per IBC2406.2 Refer to sheet Al. 1. Window does not meet the 18" bottom glazing height requirement #2 of IBC 2406.4.3. Existing bottom glazing dimension is 3,-1 3/8". Refer to sheet A2.0. d . Safety glazing not required at existing window. Window does not meet the 18" bottom glazing height requirement #2 of IBC 2406.4.3. Existing bottom glazing dimension is Y-1 3/8". Refer to sheet A2.0. e. Note added indicating required directional signage at inaccessible ramp to nearest accessible route. Refer to sheet Al.l. f. Note revised to provide 'outdoor air' at the Private Lounge, Lounge A,B, and C. Refer to sheet Al. 1. 6. Door Schedule a. IBC 1010.1.10 specific guidelines added to the Door Schedule Notes. Refer to sheet Al.l. b. Door #4 revised to a 36" leaf door. Refer to sheet Al.l. RESUB 23020 Edmonds Wag, -113, EdmorxJs, WA 98020 1 p. 206,542.3734 1 e. hekMh2dorchftects.com I w h2darchftects.com MAY 2 4 2018 . -W 5 - .. WFFMOt9q&�N' 7. Electric tankless water heater — mark'35' - location revised to be below lavatory. Refer to sheet Al. 2. 8. South Elevation a. Safety glazing not required at existing window. Window is clear of the 24" arc per IBC2406.2 Refer to sheet Al.l. Window does not meet the 18" bottom glazing height requirement #2 of IBC 2406.4.3. Existing bottom glazing dimension is 3'-1 3/8", Refer to sheet A2.0. b. Safety glazing not required at existing window. Window does not meet the 18" bottom glazing height requirement #2 of IBC 2406.4.3. Existing bottom glazing dimension is 3'-1 3/8". Refer to sheet A2.0. c. Guard limit openings note revised to 'limit the passage of a 4" sphere' per IBC 101S.4. Refer to sheet A2.0. d. Grade at deck proposed to lower 5" to accommodate framing dimension. Refer to site plan on 01 sheet and sheet A2.0. 9. Partial East Elevation a. Guard limit openings note revised to 'limit the passage of a 4" sphere' per IBC 1015.4. Refer to sheet A2.0. b. Grade at deck proposed to lower 5" to accommodate framing dimension. Refer to site plan on 01 sheet and sheet A2.0. 10. Partial West Elevation -Guard limit openings note revised to 'limit the passage of a 4" sphere' per IBC 1015.4. Refer to sheet A2.0. 11. Grade at deck proposed to lower 5" to accommodate framing dimension. Refer to site plan on 01 sheet and sheet A2.0. No change to structural sheets. 12. Main Floor Electrical Plan a. Occupancy sensor controls requirements noted in the following spaces: Lounge A, B, and C, Private Lounge, Office Storage, and Wine Storage. Refer to sheet E1.0. b. Time switch controls with manual override requirements noted at the following spaces: Hall, Bar, and Kitchen. Refer to sheet E1.0. 13. Interior Lighting - Permanent current limiting feeds proposed at Kitchen and Bar tracks to meet energy compliance. Refer to attached LTG-INT-SPACE checklist. I can be reached at 206-542-3734 or at heidiCc)h2darchitects.corn with any further questions. Regards, Heidi Helgeson Principal H2D Architecture + Design 23020 Edmonds WaW, *113, Edmonds, WA 98020 1 p. 206.542.37341 e. heid0h2clarchftects.com I w. h2darchftects.corn