Loading...
2018-0576 Zimmerman addition.pdfOV EDAI 0 City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: May 15, 2018 TO: John Zimmerman FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018-0576 Project Address: 820 Dayton ST Scope: Addition/ Remodel, SFR, VB Construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicatim! where the 'clouded' or otherwise highlij!hted chani!es can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2 nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General: I . Due to the quantity of retro fit anchors, an independent Special Inspection firm will be required to perform the inspection of all the retro fit anchors and CMU foundation alterations. For your convenience I have included our form which will be required to fill out in its entirety and returned prior to permit issuance. Your inspector will review the procedures at the time of your pre construction meeting. 2. Section R102.7.1 of the 2015 International Residential code requires additions which exceed 500 square feet to install whole house ventilation in accordance with M 1507.3. If the current home already has a whole house ventilation system and is sized in accordance with table M 1507.3.3 (1), please indicate the location and CFM rating on the plans. A2: A7: S 1.2: 3. The proposed laundry room requires a local exhaust fan with a minimum of 50 CFM. Please indicate the required fan on the plans. 4. It is unclear if the proposed exercise and bathroom are to be "conditioned space". If the space is to be "conditioned", please add the heat source, insulation details including the required R 10 perimeter insulation, weather-stripped doors from both the shop area and exterior openings. If the space is to remain "unconditioned" please indicate the means of freeze protection for the plumbing system. In either case the door from the exercise room to the shop will be required to be a minimum of a 20 minute rating with self -closing hinges and the wall separating the shop from the exercise and bathroom will be required to be covered with a minimum of 1/2" GWB on both sides. Please address and indicate on the plans. 5. It is assumbed that the "WSW 18x8" located on gridline A is for the perpendicular wall on line 6 but appears to be identifying the short wall right of the 6x6 post on line A. Please clarify and indicate on the plans. Additionally, will the 6x6 post located on the exterior wall on line 6 require a hold down device to prevent over turning? Please clarify. Please let me know if I can be of any further assistance. Sincerely, Eric Carter Page 2 of 3 Page 3 of 3