20180620135807.pdfDate: June 18,2018 To:Eric Carter, Plans Examiner, Building Division, City of Edmonds eric.carter@ed mondswa.gov From: Kelli Martin, Permit Specialist, The Permit Network thepermitnetwork@ gmail. com Comments Response Letter- BUILDING D¡V|S|ON REVIEW Application #: 81D20180354 Project: James Weis- Slngle Family Residence Project Address: 16630 74th Pl W Re: The purpose of this letter is to address comments received from you on May 18, 2018 regarding the aforementioned project. For your convenience and to expedite the review and approval process, your originalcomments are included and our responses are provided in BOLD. The following new or revised documents are incorporated by reference herein: r Sheet SP- Site Plan o Sheets A1 to 410- House Plans BUITDING DIV¡SION REVIEW Plan A3 1. The plans indicate the wine cellar as "unheated" space. The proposed door to the wine cellar must comply with Washington State Ënergy Code R 402.2.4. Please add the applicable notes to the plans. Respondent: Doug Williams- Doug Williams Design Response: note added to both doors (and cloudedf on Sheet A3, lndicating 20 min rated, self- closing doors for both wine cellar and shop. 2. lt is unclear if the proposed shop will be "conditioned" spâce. lf this space is to be conditioned, please note on the plans. lf the space is not to be conditioned, the doors leading to the conditioned space will be required to comply with R 402.2.4 as mentloned in item 1.. Respondent: Doug Williams Design Response: note added to both doors (and clouded) on Sheet 43, indicating 20 min rated, self- closing doors for both wine cellar and shop. 3. Bearn 5 and 6 supporting the deck joist exceed to allowable deflection limits. Please clarify and change the beam size of pier spacirtg on the plans. Respondent: Doug Williams Deslgn Response: Beam 5 & 6 upgraded one size to L3W and clouded on sheet 43, Beam 4 upgraded to tl% as well for aesthBtic consistency. RESU.'B JUN 2 0 zt't$ I BIJLDINGDEPAFITMENTCIÎYC)FEDMOI\Ð6 crïY c0PY 4. The 2x10 Ht #2 PT joist that are supported by beam 5 are over spanned for the proposed conditions. When sizing your framing members, be sure to use both the incising and wet service factors in addition to the minimum of 60PSF of live loading as required in table R301.5. Respondent: Doug Wllliams Design Response: All deck joists upgraded toZxl.2 and clouded on A3, Plan A4 S. The plans indicate gas fireplaces to be located in bedrooms 2 and 3 as well as the master suite. IRC 315.3 require a carbon monoxide detector to be installed within each bedroom with a fuel burning appliance. Please add the required detectors to the plans. Respondent: Doug Williarns- Þoug Williams Design Response: Carbon Monoxide detectors added for all (4) first floor Gas Fireplaces and clouded on sheet 44. lf you have questions or need additional informatien, please callor e-mail me at thepermitnetwork@ gmail.com Resp f/4¿rLâ"^ Kelli Martin, Permit Specialist 2