2018-0763 Reisinger Addition.pdf DATE: July 18th 2018 TO: Hans Reisinger hansreisineger@yahoo.com FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018-0763 Project Address: 24006 79th PL SW Scope: Addition, SFR, VB Construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General: 1. The proposed project is required to meet the minimum prescriptive requirements of the Washington State Energy code and elect additional energy credits from table R406.2. With a proposed space of 400 square feet, you will need to select .5 applicable credits from the table and indicate on the plans. 2. Carbon Monoxide detectors are required on each level of the home and outside every sleeping area. Please indicate on the plans. 3. Interconnected smoke alarms are required to be installed as part of the project. The alarms are to be located inside every sleeping room or area, outside each sleeping area and a minimum of one alarm on each level of the home. Please indicate the smoke alarms on the plans. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 4. Local exhaust fans in accordance with table M1507.4. Please indicate the minimum CFM rating and location of the proposed exhaust fans. 5. With the proposed living space being located above the garage, the requirement of 5/8” type gypsum wallboard will be required to be attached to the ceiling and ½” gyp will be required to be installed on the walls. Please indicate on the plans. Please let me know if I can be of any further assistance. Sincerely, Eric Carter