2018-1080 Hartley SFR (HARTLEY) - 190117.pdf DATE: January 17, 2019 TO: Robin Hartley FROM: Eric Evensen, Plans Examiner RE: Plan Check: BLD2018-1080 Project Address: 24304 92nd Ave W Scope: Remodel – Garage Only, VB construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: Permit: 1. It is understood that revisions to the garage and roof deck would be handled separately under permit BLD2018-1635. 2. All originally approved plan sheets appear to be replaced by the new revised sheets. Please transfer all relevant details, notes and callout to new sheets (i.e. furnace, water heater, smoke detectors, exhaust fans, window sizes, header sizes, etc.) Basement Plan: 3. An existing (2) 2x6 beam is called out as spanning north-south across the open west wall of the Family Room on the existing plan, however the existing jambs that support each end of that beam are shown removed on the new plan. Please clarify on the plans how the existing (2) 2x6 beam would be supported. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 4. An existing wall is shown on the west side of the Workshop, however roughly six feet of the wall is shown removed on the new plan. Detail 6 of the details sheet calls out an existing (2) 2x6 Beam and the two new transfer beams above to support where the wall will be removed. Please clarify on the plans that each of the beams is a new beam and indicate how each would be supported. It appears that the new (2)2x6 beam is undersized to carry the new load from the transfer beam in addition to the floor loads from the Dining Room and Living Room above. 5. On the west side of the existing Workshop, about four feet of the wall is shown removed on the new plan. While not shown, existing supporting framing is likely to be supporting the point load above from the south end of the existing opening between Living Room and Dining Room. This part of the existing basement wall is being removed. Please clarify on the plans how this vertical framing member will be supported. 6. On the west side of the existing Workshop, about six feet from the exterior south wall, the point load on the existing supporting framing is going to increase. Instead of supporting only the point load above from the north end of the existing opening between Living Room and Dining Room, it will also support the new point load above from the new adjacent opening. See Section 5 on the Sections sheet. Please clarify on the plans how this how these two adjacent vertical framing members will be supported. First Floor Plan: 7. A new deck is shown on the drawings. Would you like it to be included with this permit? If so, we’ll need the following information: a. Height of deck above ground. Uncovered decks not exceeding 200 square feet in area that are not more than thirty (30) inches above grade at any point and do not serve the required exit door are exempt from Residential Permits. b. If above thirty (30) inches, deck design and details including a guard, framing plan, connection to the house, posts, footing, stairs, and railings in compliance with the 2015 International Residential Code (IRC). c. A revised plan site plan, showing extent of deck and stairs. d. Or, in lieu of providing items b and c at this time, constructing the deck could be by separate permit. 8. Indicate (2) 2 x 12 header in two places at kitchen instead of 2 x 12. Please be aware that once the above corrections are made, subsequent city review may identify further corrections. Please let me know if I can be of any additional assistance. Eric Evensen