2018-1080 Revision (2).pdf DATE: April 15th 2019 TO: Robin Hartley FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018-1080 Project Address: 24304 92nd AVE W Scope: ALTERATION SFR, VB Construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. A3: 1. Detail bugs 5/A3 and 6/A3 have been indicated on the revised basement plan, it does not appear that these details have been included with the submittal. Please clarify. 2. The included footing schedule appears to indicate that the new footings are to be 10” in depth. Section R403.1.3.4 requires, interior bearing and braced wall footings in seismic category D to have a minimum footing depth of 12” below the top of the concrete slab. Please update the table to reflect the minimum depth as required by R403.1.3.4. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 3 A4: 3. Detail bugs 5/A3 and 6/A3 have been indicated on the revised basement plan, it does not appear that these details have been included with the submittal. Please clarify. A7: 4. Detail 6 appears to indicate a footing depth of 10”. Section R403.1.3.4 requires, interior bearing and braced wall footings in seismic category D to have a minimum footing depth of 12” below the top of the concrete slab. Please update the table to reflect the minimum depth as required by R403.1.3.4. Structural Calculations: 5. Page two and 4 of the provided structural calculations indicates that the flat roof and sloped roof snow loads are calculated at 21PSF. The design criteria used by the City of Edmonds requires a minimum of 25PSF (non-reducible). Please update the effected calculations and any structural elements. Please let me know if I can be of any further assistance. Sincerely, Eric Carter Page 3 of 3