2018-11-09 - 519 Main Street Project - SM324782 28day.pdfOTTO ROSENAU & ASSOCIATES, INC. Geotechnical Engineering, Construction Inspection & Materials Testing MASONRY REPORT Job Number: 18-0903 1 Report Number: 324782 1 Permit Number: BLD2018-0727 Project: 519 Main Street Project Client: The Four R's, LLC Address: 519 Main Street, Edmonds Inspector & Date: Satnam Singh 11/09/2018 Masonry Sub or Contractor: Build Love Global, LLC DESCRIPTION I LOCATION IBC Level of Inspection: (Projects located outside Seattle) Lev 11 E Level 2 El Ref. 17-04.5.1117-04.5.3/17-05.4 IBC (2006,2009,2012) SBC Level of Inspection: (Projects located in Seattle) Level 1 (Periodic) 0 Level 2 (Continuous) El Ref. 17-04.5.1/17-04.5.3 SBC (2006, 2009) Inspected the reinforcing steel and grout placement for a 6" CMU parapet wall at top of the building. Total height was 32". 5 1/2 cubic yards of grout were placed with pump and consolidated mechanically. The inspected work was found to be done as per approved project documents. Approximate square footage completed on this date: 400 Are anchors in place? (if required) NA Was reinforcing steel verified? Yes Is reinforcing steel secured in place?: Yes Grade of reinforcing steel: 60 Manufacturer: Cascade Is high lift grouting approved?: No GROUT INFORMATION (ASTM C 1019) Mix no./type: SA656000 Grout supplier: Salmon Bay I Grout preparer: Salmon Bay Grout temperature: 60 Grout slump: 9" 1 Total yardage: 5 1/2 1 Method of consolidation: Vibrator Grout ingredients & weights: Cement 1/11: 611 lbs., Sand: 2120 lbs., Pea 3/8: 910 lbs., Water: 310 lbs. MORTAR INFORMATION (ASTM C 780) Mix no./type: Mortar supplier: Mortar preparer: Mortar temperature: Mortar ingredients: MATERIAL INFORMATION (ASTM C 67/ ASTM C 140) Block/unit supplier: Mutual I Block/unit type: SAMPLE INFORMATION Were any samples made? Yes I If Yes - see attached report OTHER INFORMATION Weather & ambient temperature: Cloudy, 45'F Fprotection methods: Is this a re -inspection? No I if yes - original inspection date: COMMENTS Other ASTM Methods Used: Conforms X Does Not Conform Copies to Client X Engineer Others Owner X Contractor Technical Responsibility: X Architect X Building Dept. V1 W�Iffr Hansen, Project Manager This report applies only to the items tested or reported and is the exclusive property of Otto Rosenau & Associates, Inc. Reproduction of this report, except in full, without written permission from our firm is strictly prohibited. Page 1 of — 2 6747 M.L. King Way S., Seattle, Washington 98118 - Phone (206) 725-4600 or 1-888-OTTO-4-US - Fax (206) 723-2221 Form No.: ADMIN-72-07 (Rev 05113) 0 TTO R OSENA U & A SSO CIA TES, INC. Job Name: 519 Main Street Project Job Number: 18-0903 Report No: 324782 MASONRY REPORT — SAMPLE DATA Sample Description Number of Samples Sample Required Cubic Yards Size f 'm or psi Ambient Truck Ticket Temp No. No. Grouted CMU Prisms (ASTM C1 314) 3 51/2 6x8x8 2500 45 841 Y744926 Ungrouted CMU Prisms (ASTM C1 314) Grouted Clay Prisms (ASTM C1 314) Ungrouted Clay Prisms (ASTM C1314) Ai i CMU Blocks (ASTM C140) Clay Units/Blocks (ASTM C67) Grout (ASTM C1 314) Mortar (ASTM C 780) COMMENTS Set of 3 prisms were grouted for testing in the lab. Date Samples Picked Up By ORA representative: Max/Min Temperature (1st 48 hrs.): (excluding paragraph 12.1.4) PRISM INFORMATION (ASTM C1314 Date Constructed: 11/08/2018 Constructed By (Mason): Date Grouted: 11/09/2018 Block/Unit Supplier: Mutual I Block/Unit Type: Compression Test Machine Information Diameter of Spherical Seat: 13.0" Required Upper Bearing Plate Thickness: Provided Upper Bearing Plate Thickness: 3.5" Required Lower Bearing Plate Thickness: Provided Lower Bearing Plate Thickness: 5.5" PRISM COMPRESSION TEST RESULTS Avg. Avg. Avg. Gross Max Gross Height/ Corrected Prism Test Age Width Height Length Area Load Strength Thickness Strength No. Date (Days) fb�) fLl tio�) (lb.) tp-s�[) Ratio C/F fRo 1 12/7/18 28 5.65 15.67 9.15 52.16 163,860 3140 2.78 1.06 3330 2 12/7/18 28 6.65 15.88 9.20 51.98 130,510 2510 2.81 1.06 2660 3 12/7/18 28 5.70 15.75 9.05 51.13 91,950 1800 2.79 1.06 1910 Sampling & Testing Methods Used: ASTM C 140, ASTM C 1314 Avg Compressive Strength of Prisms (psi): 2630 (excluding paragraph 5.11) Height to thickness correction factor from Table 1 of ASTM C 1314 6747 M.L. King Way S., Seattle, Washington 98118 — Phone (206) 725-4600 or 1-888-OTTO-4-US — Fax (206) 723-2221 Form No.: INSP-72-07 (Rev 05113)