Loading...
2018-1347 Stepman SFR (Stepman) - 181130.pdf DATE: November 30, 2018 TO: Leonid Stepanchenko FROM: Eric Evensen, Plans Examiner RE: Plan Check: BLD2018-1347 Project Address: 1023 Carol Way Scope: Remodel SFR Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: Building Permit Application: On the application: 1. Scope of Work – Please resolve the apparent conflict between submitted application materials. Note that existing plumbing fixtures having no work done on them or plumbing fixtures being replaced at the same location, do not require a permit: a. Online Plumbing Application and Building Permit Application show: - 2 Toilets (WC) - 5 Sinks - 3 Tub/Showers - 1 Water Service Line - 1 Dishwasher - 1 Outside Faucet - 1 Clothes Washer - 1 Water Heater City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 - 1 Stove/Range - 1 Dryer - 2 Gas Fireplaces b. Submitted drawings show: - 1 Toilet at a new location - 2 Sinks in new locations - 2 Tub/Showers in new locations On the Building Plans: 1. On the plans, identify each gas appliance as “NEW” or “EXISTING”. 2. Alterations – Alterations shall comply with the provisions the Washington State Energy Code (WSEC) Table R402.1.1 without requiring the entire structure to comply, per WSEC R503.1. On the plans: a. Identify each window or skylight as “NEW” or “EXISTING.” New windows shall have a maximum U-factor of 0.30. b. Identify new ceilings as having minimum R-factor of 49. c. Each new or replacement skylight shall have a maximum U-factor of 0.50. d. Exposed exterior wall cavities shall be insulated with minimum R-15 insulation. 3. Replacement windows – Provide or maintain emergency egress and escape openings in the east and west bedrooms. Per R310.2.5 (IRC Errata posted June 10, 2015) replacement windows are exempt from maximum sill height of R310.1 and R310.2.1 and R310.2.2, provided the replacement window meets the following conditions: a. It is the manufacturer’s largest stand size window that will fit within the existing frame or existing rough opening b. It is the same operating style as the existing window or a style that provides for an equal or greater window opening area than the existing window. 4. To evaluate the proposed new beams, provide an existing framing plan to scale. Show existing roof joist layout. Indicate point loads and bearing walls below. Verify 4 x 6 ceiling joists and spacing. Also, please address in calculations. 5. New shower in North Bedroom Bath – Locate control valves and showerheads so that the bather can adjust the valves prior to stepping into the shower spray, per Uniform Plumbing Code (UPC) 408.9. 6. Reroofing – Note reroofing on the plans. Please be aware that once the above corrections are made, subsequent city review may identify further corrections. Please let me know if I can be of any additional assistance. Eric Evensen