2018-1466 Chung SFR (CHUNG).pdf DATE: December 19, 2018 TO: Sui H. & Lai S. Chung FROM: Eric Evensen, Plans Examiner RE: Plan Check: BLD2018-1466 Project Address: 725 Edmonds Way Scope: New SFR Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following items: On the Building Plans: 1. Efficient Water Heating 5A – On Sheet A2 all showerheads and the kitchen sink faucet in the house were selected to be rated at 1.75 GPM or less, while all other lavatory fixtures were selected to be rated at 1.0 GPM or less to satisfy option 5A. Add a description of the requirements of Option 5A to the plan sheets A5 and A6. 2. Efficient Water Heating 5C – On Sheet A2 the water heater was selected to be gas, propane or with a minimum EF of 0.91. Please specify fuel type and efficiency on Sheet A5. 3. Whole House Mechanical Ventilation – On Sheets A2 and A5 the supply side whole house mechanical ventilation was selected to run 75% of the time at 80 cfm, from inside City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 Laundry. Please provide a louvered door or other opening of at least 100 sq. inches per International Residential Code (IRC) Sec. G2439.5 at Laundry for make-up air. 4. Dwelling - Garage Opening Protection – Provide a self-closing device on the solid core door between the Garage and Family Foyer per IRC R302.5. 5. Use Designation – The name “Bonus Room” is not a code-related word. Code-related words include terms such as “living”, “sleeping”, “eating”, and “utility.” Please provide the use or uses envisioned for this space. Adding a smoke detector resolves this issue. 6. Structural Calculations – Lateral analysis at upper level walls has shear forces being gathered in a wall between Grid 3 and Grid 4. How are these shear forces carried to grade? Please be aware that once the above corrections are made, subsequent city review may identify further corrections. Please let me know if I can be of any additional assistance. Eric Evensen