Loading...
2018-1643 Trout Holdings Addition.pdf DATE: February 5, 2019 TO: Jennifer Wedderman FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018- 1643 Project Address: 23309 76th AVE. W. Scope: Addition to SFR, VB construction, Plumbing and Mechanical included. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. This building plan review cannot be completed until we receive the following item: General: 1. Please provide structural calculations for both gravity and lateral to support the designs provided on the structural pages stamped by Engineer of Record, Ercin Sahin. A1.0: 2. It is indicated on the plans that WSEC energy credit 1A has been selected as part of the required additional energy credits. The description of 1A is not complete. If this credit is still intended to be utilized, please update the description as shown in table R406.2 of the Washington State Energy Code. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 A2.1: 3. It appears that the window within the shower enclosure between bedroom 3 and 4 is located within “hazardous location” and will need to be “safety glazed”. Please indicate on the plans. 4. Bedrooms 3 and 4 appear to show windows on the plans but do not indicate if they are compliant with IRC R310.2.1 and R310.2.2. Please indicate the size and operational style of the proposed windows on the plans. 5. Energy credit 1A has been elected on page A1.0 as part of the submittal, credit 1A requires R10 insulation around the perimeter and under the entire slab of the addition. Please indicate the required foam and vapor barrier on the plans. 6. It is noted that the “whole house fan” is to be 320 CFM but does not mention the maximum sone rating in accordance with M1507.3.4.2. Whole house fans within 4’ of the interior grille must not exceed 1 sone. Please verify that the fan selected will comply and note on the plans. 7. Sheet A2.1 and S 1.0 the floor plans and locations of equipment appear to be different, please clarify and reconcile the plan sheets. S5.0: 8. Note 9 on page S 5.0 indicates a Simpson SSTB anchor bolt is required. The diameter of the SSTB is specified but the minimum length is not. Please indicate the minimum length of the SSTB for each style of hold down on the plans. Upon review of the resubmitted information, additional comments may be generated Please let me know if I can be of any additional assistance. Eric Carter