Loading...
2019-0304 Mullet (Strobl).pdf DATE: April 23rd 2019 TO: Jacob Strobl jacob@strobldesign.com FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2019-0304 Project Address: 18909 Olympic View Drive Scope: ADDITION, SFR, VB Construction Plumbing and Mechanical included Please be advised that the building plans for the above referenced project have been disapproveddisapproveddisapproveddisapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed.... Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italicsItems that recur on this list appear in italicsItems that recur on this list appear in italicsItems that recur on this list appear in italics. A complete review cannot be performed until A complete review cannot be performed until A complete review cannot be performed until A complete review cannot be performed until the revised plans/documents, the revised plans/documents, the revised plans/documents, the revised plans/documents, including a written response including a written response including a written response including a written response in itin itin itin itemized letter format emized letter format emized letter format emized letter format indicating where the indicating where the indicating where the indicating where the ‘clouded’ ‘clouded’ ‘clouded’ ‘clouded’ or otherwise highlighted or otherwise highlighted or otherwise highlighted or otherwise highlighted changes can be found on the changes can be found on the changes can be found on the changes can be found on the revised revised revised revised plansplansplansplans, , , , have been submitted to a Permit Coordinator. have been submitted to a Permit Coordinator. have been submitted to a Permit Coordinator. have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. A3: 1. The Energy Code notes indicate a local exhaust fan with window vents will be the means of “whole house ventilation”. The plans do not appear to indicate the location, CFM, or hours of operation. Please indicate the location of the local exhaust fan, CFM and operation. 2. The provided window and door schedules indicate a minimum U value of .30. The window and door notes indicate a minimum value of .28. Please clarify and indicate on the plans. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 3 3. In accordance with IRC R302.3, the ADU must be separated from the existing residence with a minimum of 1 hour fire rated construction. Or as indicated on page 3 of Handout P1 provide by the City of Edmonds, in lieu of the 1 hour construction interconnected smoke and CO detectors can be installed in such a manner that the actuation of one alarm will activate the alarms in both primary and accessory dwellings. Please indicate on the plans which method will unitized on this project. 4. Section 606.3 of the 2015 UPC requires an independent water shut off for each unit. Please indicate on the plan the location of the water supply shutoff on the plan. Please let me know if I can be of any further assistance. Sincerely, Eric Carter Page 3 of 3