2019-0603 Kanon Deck.pdf DATE: June 19, 2019 TO: Foster Kanon FROM: Eric Carter, Plans Examiner RE: Plan Check: BLD2018-0603 Project Address: 23302 Humber Lane Scope: New deck and roof structure. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General: 1. The submittal does not appear to include the required supplemental structural calculation packets. Please provide two sets of calculations that have been prepared and stamped by the designing Engineer. S2.1: 2. The 2x10 joist noted on the plans, spanning 11’ are overstressed for the anticipated loads. These joists will need to be of a larger size or change the on-center spacing, please take into account of a minimum of 10PSF of “dead load”, 60PSF of “live load”, and the applicable “wet service” and “incising” factors when sizing your framing members. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 3 3. Lateral load connections are required per IRC 507.2.4. Please indicate the locations of these connections on the plans. 4. It does not appear that a ledger detail has been provided on the plans. Please provide a detail that indicates the size of the ledger, anchor spacing and pattern of fasteners on the plans. Please let me know if I can be of any further assistance. Sincerely, Eric Carter Page 3 of 3