Loading...
2019-0909 Sebastien.pdf DATE: September 11, 2019 TO: Architects NW FROM: Donovan Akau, Plans Examiner RE: Plan Check: BLD2019-0909 Project Address: 21222 Pioneer Way Scope: New SFR, ADU, R-3, VB Construction. Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. Items that recur on this list appear in italics. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the ‘clouded’ or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General: 1. The primary residence and the proposed ADU must act as independent dwellings. Please indicate on the plans where the electrical panel, water shut off, and heating appliances will be located for each dwelling. These locations must be readily accessible to the dwelling they service without having to access through the adjacent dwelling. Please indicate on the plans where the water shut off(s) and electrical panel(s) will be located for the primary residence and ADU. 2. The notes on the proposed plans appear to indicate that an electric dryer is to be installed for the ADU. The permit application indicates a gas line is to be installed for both dryers. Combustion air will be required to be provided to a fuel burring appliance. Please clarify and indicate on the plans. 3. The proposed ADU will require a whole house mechanical “whole house” ventilation in accordance with M1507.3.1 of the 2015 International Residential Code. Please indicate how the requirement will be achieved on the plans. 4. Please correct the calculations for the deck and make and corrections to calculations used for the deck of this project. See amended table R301.5, 2015 IRC, or omit from plans if there is no deck for this project. 5. Please have Engineer of record stamp/sign the plan sheets that has calculations done by Engineer for this project. 6. Have Architect/Engineer review the spans and scale for this project. It appears that the spans and scale is not in correspondence with calculations provided by Engineer of record. 7. Plans indicate a hot water tank located in the garage. Application indicates a tankless hot water tank. Make corrections/clarify. 8. Please indicate and provide location of hose bibs for this project on the plans and the permit application. City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 2 9. Please clarify floor drain /sink (5) on permit application. 10. Indicate the location of the Heat Pump Unit on the plans. I have reviewed the most recent WSFU tables sent via email on 5/21/19. The provided information is in compliance with Appendix C of the 2015 UPC. A ¾” water meter with a minimum of a 1” water line will be sufficient. Please add the provided tables to the plans. Upon review of the resubmitted documents, additional comments may be generated . Sincerely, Donovan Akau