Loading...
2019-1519 Murphy Residence.pdf DATE: December 19, 2019 TO: James Murphy FROM: Kevin Bloomfield, Plans Examiner RE: Plan Check: BLD20191519 Project Address: 420 6th Ave North Scope: Remodel and Addition Thank you for submitting your plans to the City of Edmonds for review. We have completed an initial review of the project mentioned above. For this project to move forward a few items will need to be addressed. Once a revised set of plans, including a written response to the list of the items contained in this letter are resubmitted, we can complete the review. Some items may require a review by other divisions, such as Planning, Engineering, or Fire and will be noted as such. Resubmittals can be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. To complete the review the following items will need to be addressed: General: 1. The Engineer of Record (EOR) stamp has expired (10/31/2019). Please have EOR restamp with current stamp. 2. The City of Edmonds has adopted the 2015 Washington State Energy Code (2015 WSEC). This will apply to your remodel and addition. It appears the home is now approximately 1600 SqFt. According to the 2015 WSEC, Section 406.2, item two, this would make this home a “Medium Dwelling Unit”. As a medium dwelling unit the home will need to satisfy 3.5 energy credits. 2015 WSEC Table 406.2 “Energy Credits” will assist you in finding the credits you qualify for and how to reflect those credits on the plans. Page A3 3. Bedroom 1 bathroom does not show a window above the tub. The elevation reflects a window in this area. Please correct the plans to show which situation is correct. If glazing is City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 Page 2 of 3 used in this area and the bottom sill is below 60”, the window must be safety glass. R308.4.5 Glazing and Wet Surfaces 4. Window at entry is closer than 24” to the entry door. This glazing should be safety glass. R308.4.2 Glazing Adjacent to Doors 5. Smoke Alarm and Carbon Monoxide Alarm locations must be shown on plans. Refer to Section R314 Smoke Alarms and Section R315 Carbon Monoxide Alarms for locations and requirements. 6. Mechanical ventilation is required for the bathroom(s) and cooktop in the kitchen. It appears that these are not identified on the plans. Please provide this on the plans for this project to include the CFM for each per R303.4 Minimum ventilation performance. 7. With the addition of the 680 sq. ft. of habitable space, you will be required to have a whole house ventilation system. R303.4. Please indicate this on the plans. 8. The laundry room contains a dryer and furnace. This will require make up air and ventilation Section M1507 Mechanical Ventilation. Indicate this on the plans for this project. 9. The door separating the garage from the home must be fire rated. Dwelling-Garage Opening and Penetration Protection openings between the garage and residence shall be equipped with solid wood doors not less than 13/8 inches in thickness, solid or honeycomb-core steel doors not less than 13/8 inches thick, or 20-minute fire-rated doors, equipped with a self- closing device. R302.5.1 Opening Protection 10. Plans indicate “SH” in the mechanical room. Please identify what this abbreviation means. 11. A handrail will be required for the stairway. The handrails must comply with Section R311.7.8 Handrails, Handrails shall be provided on not less than one side of each continuous run of treads or flight with four or more risers. 12. If entry porch is over 30” in height a guard will be required. If guard is required please include a detail on the plans. If entry porch is new please include a detail of the ledger and all connections including any hold downs or tension devises for the deck as well as the guard per Section R312 Guards and Window Fall Protection Page A4 13. As with page A3 safety glass is required at doors to deck, window at top pf stairs, large window in bedroom, and glass in shower. 14. Also as with page A3 smoke detectors and Carbon Monoxide Alarms are required in this area also. Please indicate on the plans location and type of device. All smoke alarm and CO Alarm in the home should be interconnected as outlined in Section R314.4 Interconnection. Page 3 of 3 15. Detail for second floor porch is required. Please indicate all connections and ties. Include lumber type and size used. The details should reflect any tension ties used to connect deck to home. 16. A detail of the guard for the second floor deck is required. Please refer to Section R312 Guards and Window Fall Protection for code requirements. Page A5 17. The new roof for the second floor will need ventilation. Please follow Section R806 Roof Ventilation for guidelines on this requirement. R806.2 Minimum Vent Area The minimum net free ventilating area shall be 1/150 of the area of the vented space. Exception: The minimum net free ventilation area shall be 1/300 of the vented space provided one or more of the following conditions are met:  In Climate Zones 6, 7 and 8, a Class I or II vapor retarder is installed on the warm- in-winter side of the ceiling.  Not less than 40 percent and not more than 50 percent of the required ventilating area is provided by ventilators located in the upper portion of the attic or rafter space. 18. Please identify the location of roof, ridge or attic ventilation on the plans. Include calculations to meet the code requirements. If you need any clarification or have any questions at all, please feel free to call anytime. Kevin Bloomfield