2091_001.pdf'�&_IDA I 1p- C6019 EDEPE BLOW DOOR TESTING Date: June 25, 2019 Time Started: 2:32 I'M Location: 201 Main Street, Edmonds, WA Building Type: Multi -Family Unit: 203#, Second Floor comer unit with one adjacent units Test: Tester: Tester Location: Outside Air Temp: Inside Air Temp: Wind: Test Results: Compartmentalized Testing Retrotec 1000 Series Front Entry 72 OF 68 OF Negligible CFM50 CFA (SF) SLA SLA Limit Ceiling Ht (Ft) CV (CF) AC50 AC50 Limit 843 1151 0.000221 0.0003 8 9208 4.346 <+5.0 Notes: The test resulted in an acceptable SLA of 0.000221 (limit is 0.00030) and an acceptable air change rate AC50 of 4.346 (limit is 5.0). Flow was noted at the electrical outlets and light switches. Leakage was also noted at the wall heater and through the light openings. Because compartmentalized testing was accomplished, it is reasonable that a percentage of the leaks are from the adjacent units. Steve Depew, PE Depew, Inc. InDepew, Inc. 1834 SW 152"', Burien, WA 98166 . Ph: 206.229.7475 www.denewpine.com I of 3 EE EPE GLOSSARY AC50 Air Changes per Hour at 50 pascals pressure differential CFA Conditioned Floor Area CFM50 Cubic Feet per Minute at 50 pascals pressure differential Compartmentalized Testing Testing of a single unit with a single fan allowing for leakage through both exterior walls and adjacent interior conditioned spaces. See Figure I below. Figure I CV Conditioned Volume SLA Specific Leakage Area SLA = (CFM50 X.055) / (CFA X 144) Test Checklist Close all windows, doors and fireplace and stove doors. Close all dampers including exhaust, intake, make-up air, backdraft and flue dampers. Since you will be depressurizing the house, dampers in bath fans, etc. will be sucked closed during the test and will therefore not negatively affect the results. Notes- The range hood was not sealed beyond the barometric damper. Both bathroom exhaust fans were sealed. The drier vent was attached to the drier and not sealed. Make sure plumbing traps are filled with water. TDepew, Inc. 1834 SW 15211, Burien, WA 98166 . Ph: 206.229.7475 www.deveWpinc.com 2 of 3 EPE Z Leave doors between heated areas open. Z Open access hatches to conditioned attics and/or conditioned crawl spaces. Notes: N/A Z Seal exterior openings for continuously operating ventilation systems and heat recovery ventilators. Notes- The through wall heat pump did not require sealing. Z Turn off heating and cooling systems but do not seal supply or return registers. Notes: N/A Adjust all combustion appliances so that they do not turn on during the test. Z Install the blower door in an exterior door opening and connect hoses from the manometer to the blower door fan and the exterior pressure tap. See manufacturer's instructions for correct set-up. Z Depressurize the house to -50 Pascals. Z Record the flow rate. 75 Depew, Inc. 1834 SW 152md, Burien, WA 98166 . Ph: 206.229.747S www.depewpinc.com 3 of 3