Re OCiSlæ & 181 11 84th Avenue Anchor Load Testing
Mayes Testing Enqineers Project Number M7181727
Dear Mr. Lucia
July 8, 2019
Joe Lucia
Lucia Engineering
7037 12th Ave NE
Seattle, WA 981 15-5619
The test load was applied via a cal¡brated
Enerpac RCH-302 thru-hole hydraulic ram and
digital gauge assembly (shown right). ln
accordance with ASTM E3121 load testing
procedures, we also used a reaction beam to
distribute the load away from the substrate in
which a failure cone could develop.
We understand the HDTB anchors prescribed a
test load of 5,600 pounds-force (lb-f), while the
HD12 anchors were prescribed a test load of
20,000 lb-f. All anchors were tested at their
prescribed loads for 5 minutes or until failure,
whichever came first.
Anchor Load Testing Setup
As requested, on June 27,2019, Mayes Testing Engineers performed load testing of
hold-down anchors at the above referenced project at 181 11 84th Avenue West in Seattle,
Washington.
Background
The Residence at 18111 84th Avenue West is currently under construction. Part of the
construction includes the use Simpson Strong-Tie HDTB and HD12 hold-downs for seismic
and wind loads. We understand that these anchors did not receive inspection during their
installation. Thus, load testing of the anchors was required for permissible use.
Test Procedures
There were approximately eight HDTB and eight
HD12 anchors installed; two of each
(approximately 25o/o) were selected for testing in
conjunction with the contractor based on
accessibility.
Test Results
All anchors tested held their required loads for the minimum S-minute duration without
failure or indication of overstress. The general locations of the tested anchors are shown on
the attached plan.
We trust this provides you with the information you require at this time
Respectful ly Submitted,
M AYES ÏES I'NG ETVG''VEERS
t,MÈkael E. ïhompson
Field Engineer
Encl: Anchor Testing Locations
r, P.E
Special Projects Manager
MAYES TEST'NG ENG'NEERS,
'NC,
QC 18109 & 18111 84th Ave Anchor Testing Locations
Mayes Testing Engineers Project Number M7181727
$)
r '$'
.1-
ã'
t, I
rô¡ ffiÉw f¡
ñY@!Ere¡øiñrAAgÐ É84ÉÉÄÊÀatMË6 <l
l*=l!rþ Ill
L_!
i;.---- -rll'llr.q;-
ilRí- .
.l _i
H,K
'Ì:-
s11€4ol I
,-t-ì
?lñtþ ¡
-rÐ4+¡
.t?
!l!
(i;m 'ilñr*6 ¡ÁN
ffi ffib.-ñfÁrt¡€Æ@@ffi_ffifrñ*@trct
d5&0 gD
4îñ¡ff
Ð8/æ6ìÆ*&Mff
YFJñ EûO d F{-E'trHãFffiru
lld crMYg&ffi
iãö¡æ¡b' iæmrr ru'
w, Wf 5ÀilY
úircaøæó-w&
/r*@lN
fT
þ- &vlæ 5lÁlüaY \
:,ffi!€x&@ó \ffir¿@ßrtrøaøÂ&:&@. óÆqMffilIWE6 q¡
üitþ SY5Ë fúilÚÉ
ffil@tÆÈq
1¡Ef rltR
#= HDTB Anchor Test
= HD12 Anchor Test
1
s- !sãg**s-é,i rE!
*! ü gô'æ d ü!-9 S€t-Éa*î*wfqE*{¿! - * {. .?¡ :
'Þ;
ó¡€À6Ë
rr:
Èau.
!F.
¿tg*f
2
'ی'
4
MAYES TEST'NG ENG'NEERS,
'NC,