210 ST SW - 7104_Gurinder SFR_BLD20060989_2.doc City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections Plan Check : Date: # BLD20060989 October 4, 2006 Project Name/Address: Gurinder SFR / 7104 – 210 St SW Contact Person/Address/Fax: Gurinder Grewal / 24226 10TH AVE S, DES MOINES, WA 98198 / Ph 206- 941-5454 / Fax 206-870-2772 / g_gurinder@hotmail.com Reviewer: Edward SibrelDivision:Engineering During review of the subject submittal it was found that the following information, corrections, or clarifications will need to be addressed: Please disregard the previous Engineering Plan Review Correction of September 27, 2006. 1.Grading quantity has been calculated to be 150 CY. A grading permit will be required. Planning has been notified of this requirement. 2.Drainage / Detention  The proposed total impervious surface for the site, 2277 sf, triggers the requirement for a detention system. Please include an appropriately-sized system for your project. A handout has been included for your review.  Please note how and where the roof drains tie into the required detention system.  Note how and where the footing drains are to empty (Note: footing drains are not to tie directly to the detention system. See handout for details.  Show how the detention system ties into city storm conveyances.  Show how the driveway drains to the detention system. 3.Utilities  Show the side sewer from the house to the main. Be mindful of the requirements for cleanouts at the property line and at the house.  Show the water service line from the house to the meter. NOTE: the meter will be required to be th placed at the right-of-way line at 210 St, SW.  Note a minimum 10’ separation requirement between the water and sewer lines. DATE FAXED 10/4/06 PAGE _1___ OF __2_ 4.Site Plan  Because of the requirement to run the water service line from the house to 210 St SW, the site plan must include the entire length of the access road, with the water line location noted.  Please locate the sewer main in the access road.  Please note the actual location of the existing catch basin in the access road. Please resubmit three copies of the revised plans/documents to a Development Services Coordinator. Please contact me at 425-771-0220 if you have specific questions regarding these plan corrections. DATE FAXED 10/4/06 PAGE _1___ OF __2_