210 St SW - 7220_Crosby Warehouse_20071072_3.pdfCity of Edmonds 121 5TH AVENUE NORTH - EDMONDS, WA 98020 - (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning - Building - Engineering Plan Review Corrections Application 4: BLD20071072 Date: April 15, 2008 Project Name/Address: Crosby Warehouse/ 7220 —210 St SW Contact Person/Address, Fax or E-mail: Adam Clark / FAX 425-742-8130 Reviewer: Edward Sibrel Division: Eneineerine During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please redline plans or submit three (3) sets of revised plans/documents with a written response to each of the items below to Marie Harrison. MEMO: The engineering program manager, Jeanie McConnell, has proofed the review. And alterations she has made has been hightlighted. —Ed First Review date — 12/19/07 Second Review date — 4/9/08 GENERAL 1. OK. Yott will be r-equiFed to place a bond for- 120% of the City approved estimate for- the off site improvements. The 2.2% 2. OK. 3. Needs Work: A Traffic Control and Haul Route plan is missing. Please include with your next submittal. a. The Haul Route may be superimposed on the Vicinity map, rather than expressed in sentences. In order to minimize disruption of residents, please adjust route to the site to be from SR99 to westbound 212 St SW, then north on 72 d Ave W, then west on 2101h to the site. b. A Traffic Control Plan has not been submitted. 4. OK. Sheet A1.1, Site Plan 1. OK. 2. Trash enclosures. The Recycling Coordinator notes that the location of the trash enclosure is acceptable, but requires a interior width of 16' for the enclosure. He also recommends that the gates be secured to wooden or steel posts, rather than directly to the CNW walls, as the expansion bolts in the CNW will work themselves out in time. 3 OK. 3. 1. Many of the site plan notes and flags no longer match their corresponding details. DATE FAXED 4/15/2008 PAGE I of 2 3.2. Under "Utility Districts," change "Olympic View" to "Edmonds." Sheet C-1, Clearing, TESC & Grading Plan 1. OK. 2. OK. 3. OK. Sheet C-2, TESC Details OK Sheet C-3, Street and Parking Plan 1. OK. 2. OK. 3. OK. Sheet C-4, Grading and Drainage Plan 1. OK. 2. OK. 3. OK. 3. 1. New CB near NW comer of property lists the outlet invert at 68.3 — should that be 86.3? 4. OK. 5. OK. Sheet C-5, Street and Parking Plan (Water and Sewer Plan) 1. OK. 2. OK. 3. OK An !FFiga4ien SpFillkleF Pfffflit is to be obtained fmiem Ptiblie WE)Fks. Gen4aet Linda MeMuFphy, GFOSS Qfflfleetiffl COR Speeialist at 4 2_5 77 1- 0- 2_1 -5. 4. OK. 4. 1. If irrigation is to be separately metered, then a direct connection to the main, within the three -valve cluster, is required. If not, then connect the irrigation line between the domestic meter and the RPBA. 5. Fire. Refer to the Fire Marshall's comments: a. Provide details and plans for a DCDA.... >>The DCDA shall be located within a vault, within 10' of the property line, per E7.8.1 and the FD's most recent comments. b. Not Done: A Fire Connection Permit shall be submitted at the same time as the next civil plans submittal. c. Note that a three -valve cluster shall be required on the main. >>The fire and domestic lines in the close-up view of the cluster are reversed from their original positions in the plan view. OK. OK. Please contact me at 425-771-0220 or by e-mail at sibrel6i�cixdmonds.waxs if you have specific questions regarding these plan corrections. DATE FAXED 4/15/2008 PAGE 2 of 2