235th_PL_SW-10506_Steinman_SFR_BLD20080269.pdf
City of Edmonds BLD 20080255
TH
121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
PUBLIC WORKS DEPARTMENT
Planning • Building • Engineering
Engineering Plan Review Comments
Permit Application :Date:
# BLD20080269 5/06/08
th
Project Name/Address:
Steinman – 10506-235 PL SW
Contact Person/Address, Fax or E-mail:
Ron Steinman – oshunroamer@aol.com
Reviewer: JENNIFER COLLINS Division:
ENGINEERING
During review of the subject submittal, it was found that the following information, corrections, or
clarifications would need to be addressed. All Handouts referred to in these comments can be accessed at
our website: www.ci.edmonds.wa.us under City Government / Development Services Department /
Engineering Division then scroll down to Handouts:
As preliminary approval has not been granted for short plat and civils have not been submitted and / or
approved for development. This application will be reviewed as a single family residence only. Please
note additional improvements may be required with short plat.
1)Utility Plan – needs to be consistent with site plan – removing existing house, showing only one lot,
etc. Revise sheet title as this is not the preliminary development plan.
2)Two water meters are shown. Will existing meter be removed / abandoned?
3)Clearly show sewer for new house and existing portions to be removed. Label future stubs
accordingly. Obtain approval from Olympic View Water & Sewer District to reuse existing
lateral for your side sewer.
4)Show all cleanouts with the invert elevations. Cleanouts need to located at all 90 degree bends,
property line, at the home, and every 100’ from the previous cleanout.
5)Show a 6” cleanout at the property line with a 12” cast iron lamphole cover.
6)Show Show the water service line from the meter to the house.
7)Only one driveway access shall be provided to the new residence. Please remove existing
driveway.
8)Entire property needs to be shown on the erosion and sediment control plan. Erosion control will
also need to be in place for the demolition of the existing home and removal of the existing
driveway.
DATE E-MAILED 5/7/08 PAGE()
1
City of Edmonds BLD 20080255
TH
121 5 AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221
Website: www.ci.edmonds.wa.us
PUBLIC WORKS DEPARTMENT
Planning • Building • Engineering
Engineering Plan Review Comments
9)Provide grading calculations. Show bottom and footing elevations for each step, if any, in the
foundation to determine grading quantities. Also show existing and proposed contours.
Storm Water
Our storm water engineer, Don Fiene, is in contact with LSA, your engineer for this project, to discuss
obtaining an easement for city storm system. Storm drainage requirements for this property will be
determined once this has been resolved.
Please resubmit 3 copies of the revised site drawings and associated documents with a written response to
each item to an Engineering Technician. Please contact me at 425-771-0220 ext 1321 or by e-mail at
collinsj@ci.edmonds.wa.us if you have specific questions regarding these plan corrections.
DATE E-MAILED 5/7/08 PAGE()
2