2458_001.pdfMedical Gas Services, LLC Inspector of Record Report Date: September 5, 2019 Job Number: 2028 Contractor: Dr. Radu Wolf Date(s) and Time(s) of Testing: September 3, 2019 — 0900 hrs. Facility: Smile Again — Radu Wolf DDS 7935216 ffi Street SVV, Suite A Edmonds, WA. 98026 Scope of Work: Verification of cylinder storage room modifications. Medical Gas Services, LLC 6355 NE 151s' Street Kenmore, WA 98028 425-877-9623 SEP 2 3 2019 LX-- VtJ-(-'PV ENT SERVICES Our firm certifies that the verifier(s) named in the report are properly trained and certified to perform the activities required. All test and measurement equipment is properly calibrated and maintained. As a representative of Medical Gas Services, LLC the verifier(s) named in this report have conducted testing and verification of Medical Gas piping systems and related equipment to certify the following on the above date. 1. General Findings: A. Some Medical Gas and Dental system components in area tested are in compliance with NFPA 99 (2012ed). Level 3, Dental. Note: Existing Equipment and Systems. NFPA 99(2012ed) #5.3.1.4 - An existing Level 3 system that is not in strict compliance with the provisions of this standard shall be permitted to be continued in use as long as the authority having jurisdiction has determined that such use does not constitute a distinct hazard to life. 1796-1 nspectorOf Record Pg. 1 of 3 Med-ical Gas Servicesq LLC Medical Gas Services, LLC 6355 NE 151st Street Kenmore, WA 98028 425-877-9623 111. Manifold /Alarm: A. Manifold: 1. Brand: Porter 2. Model Number: Vanguard 3. Serial Number: 4-3591 B. Alarm: 1. Brand: Porter 2. Model Number: Vanguard 3. Serial Number: KD98526 111. Dental Equipment: A. Dental Air: 1 . Most system air components in compliance with NFPA 99(2012ed) 2. Brand: Cattani 3. Model Number: CT-38/1 4. Serial Number: CA2000051 5. Configuration: Duplex 6. Horse Power: Unknown 7. intake: Inside (Same) 8. Pump: Oil Less B. Dental Vacuum: 1 . Most system vacuum components in compliance with NFPA 99(2012ed) 2. Brand: Ramvac 3. Model Number: 809E-1050.1 (Bulldog) 4. Serial Number: QT1 101138 5. Configuration: Simplex 6. Horse Power: 1 7. Vented to outside, Yes C. Amalgam Separator: 1. Brand: Solmetex 2. Model Number: Hg5 3. Serial Number: CC-L-386569 IV. Cylinder Storage: A. Location: Remote B. Ventilation: Yes C. Cooling Sprinkler: Yes D. Door labeled: Yes E. 1 Hour Rated: No F. Cylinders Secured: Yes 1796-1 nspectorOf Record Pg. 2 of 3 Medical Gas Services, LLC Medical Gas Services, LLC 6355 NE 151st Street Kenmore, WA 98028 425-877-9623 V. Witness: Sophia Wolf — Smile Again V11. Comments: A. Interior finishes not made of non-combustible materials. B. Natural ventilation does not have an opening within one foot of the floor. V1111. Recommended Corrections: A. Finish interior of cylinder storage room with non-combustible materials. B. Relocate one ventilation opening to within one foot of the floor per NFPA 99. Tested By: Harry Pomeranz — ASSE 6030 Verifier 1796-InspectorOf Record Pg. 3 of 3