Loading...
3.pdf0,� E, DATE: May 10, 2006 City of Edmonds, PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 TO: Ron Hammill 1160 Sea Vista Pl. Edmonds, WA 98020 FROM: Jenny Readwin, Plans ExamineV RE: Plan Check # 05-421 Project: Garage/Deck Addition ProjectAddress: 1160SeaVistaPl. During re -review of the above noted application, it was found that the following information, corrections, or clarifications are needed. 1) Still Need Expand the floor plan to show the existing garage and any other portions of the house that is connected to this addition. 2) Still Need Expand the section detail to show the roof deck framing (i.e. how it will be sloped 2 . % minimum, decking material, floor drains, guard rail height, etc.). 3) Still need and Engineer of Record needs to cross reference details in calculations to their location as well (i.e. retaining wall andfoundation details). Cross reference all details to their location on the plans (i.e. where does the bearing wall on slab detail apply?). 4) ok Still need Cross reference the retaining wall detail location on the plans as well as sit6 I 6 Still need Provide letter ftom Dennis Bruce, Geotechnical Engineer stating that he ha t the retaining wall detail and ih-a��t —isc�niiisfe-nff-with his report recommendations. Also, e h jm im clarify if the wall is supporting a surcharge from the garage/driveway. If so, detail must be stamped and signed with calculations by a Washington State Licensed Engineer (see retaining all handout attached). 7) ti " need Special inspections are required for the following. Complete the enclosed special ection agreement signed by the owner, the general contractor and the special inspector and submit to the City for approval prior to issuance. • Retaining wall construction • Soil bearing verification Placement of fill and compaction * Epoxy holdown and anchor bolt retrofit installation 8) New: Details in the calculations (i.e.2x8 joists detail A) do not appear to reflect actual conditions i.e. 2x8 joists shown in the pictures are notched and EOR shows them bearing on the wall. Will the existing joist be replaced? If not Engineer of Record needs to address actual conditions. 9) New: Engineer of Record to specify connection ofjoists to existing wall of house (expand detail A to show this. Pictures appear to show them hanging but off of what? EOR needs to address or provide fix. Please redline plans or submit two (2) sets of revised plans/documents (affected sheets only) with a written response to each of the above items to a Permit Coordinator. Page 2 of 2