3108_001.pdfHANSON DESIGN KRISTIN HANSON 652 ALDER ST EDMONDS 98020 RE: BLD 2019 -1376 RITTER 719 CASPERS PLAN REVIEW RESPONSES: WRITTEN REPONSES HERE. 11-25-2019 KEVIN BLOOMFIELD MARKED IN R-E-0 ON PLAN SETS. PmrLr" - 1. DOORS W/O LANDINGS: DOOR AT BOTTOM OF BASEMENT STAIRS AND LOWER END OF UPPER FLOOR STAIRS NOW DO NOT HAVE DOORS. SO LANDING SPACE AVAILABLE EACH LOCATION. 2.HANDRAIL DETAILS: TYPE I & 11 DIAGRAM pg 4. 3.WATER HEATER: A.0. SMITH # EG-12 50 R22DV 50 gal. ELEC. FURNACE: DAIKIN #DM96VCO 603BN 96% AFUE/ GAS. 4.13ASEMENT: IT IS HEATED (error). INSULATION LISTED pg 4. INSULATION WILL EXTEND AROUND'MYSTERY SPOT'. NO NEW HOLES TO BE DRILLED IN NORTH BASEMENT WALL. EXISTING. 5.CARBON MONOXIDE ALARMS: NOW ON ALL 3 FLOORS. VMYSTERY SPOT' CONCRETE 6 Il + WALLS EXTEND FLOOR —CEILING. TINY ACCESS IS 12 X 5 INCHES TO BE SEALED. AREA IS FILLED ALMOST TO CEILING WITH RUBBLE. WILL BE INSULATED AROUND THE BASEMENT SIDES AND FLOOR INSULATION IN KITCHEN. 7. BARRIER AT WEST ARCADIA DOOR: NEW BARRIER DETAILS Pg. 6 8. CFM FOR FANS: NOTE Pg 4 BATH: 50 CFM LAUNDRY: 50 CFM KITCHEN: 100CFM 9. 4 X 12 BEAMS CALCS. ATTACHED. 1. ENGINEER'S RESPONSE ATTACHED. 10. HEIGHT OF PORCH: Pg 6 HEIGHT (PORCH —GRADE) IS 36 INCHES. GUARDS, HANDRAILS REQUIRED, NOTED. ii. PORCH FOOTINGS: 16" x 16" x 24" DEEP Pg. 6. HOPE THIS IS SUFFIENCT. PLEASE CONTACT ME IF MORE IS NEEDED. THANKYOU., "Lit" KRISTIN HANSON HANSON DESIGN hansondesign@hotmail.com Good Morning Kristin, 12-6-2019 Please see the attached supplemental structural calculation for the Ritter Residence. Looks like I upsized after I completed the calcs to make room for the hangers from both sides. Certainly doesn't seem like it warrants its own calculation but ok! :) The response to the letter should read something along the lines of: "Reference attached supplemental structural calculation for 412 beams. As I mentioned previously - the complete structural drawing set included the plans, so perhaps include the stamped plans in the resubmittal, and then there should be no reason for a structural stamp on any architectural sheets. Let me know if you have any questions. Thanks so much! Caitlin Caitlin Rose Engineering, LLC caitliti@caitliiii-oseeiiqiiieei-iiiq.coi-n 425-301-6554 www.caltlini-oseengineet-ing.com City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 ON DATE: November 25, 2019 TO: Kirsten Hanson FROM: Kevin Bloomfield, Plans Examiner RE: Plan Check: BLD20191376 Project Address: 719 Caspers St Scope: Seal Basement and remodel adding one bedroom in attic space Thank you for submitting your plans to the City of Edmonds for review. We have completed an initial review of the project mentioned above. For this project to move forward a few items will need to be addressed. Once a revised set of plans, including a written response to the list of the items contained in this letter are resubmitted, we can complete the review. Some items may require a review by other divisions, such as Planning, Engineering, or Fire and will be noted as such. Resubmittals can be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. To complete the review the following items will need to be addressed: Page 4 1. Plans reflect a door at the bottom of the stairs to the basement and a "barn Door" at the bottom of the stairs on the main floor. A landing the width of the stairs is required in these locations. A landing is required at front porch stairs also. R311.7.6 Landings for Stairways There shall be a floor or landing at the top and bottom of each stairway. The width perpendicular to the direction of travel shall be not less than the width of the flight served. 2. Please include a handrail detail that addresses the requirements of R311.7.8 Handrails. Include depth height and cross-section in the detail. 3. The plans indicate the water heater is being used to qualify for the energy credit. Please include model and efficiency rating on the plans. Also include the same information for the "New Furnace". 4. This space is labeled as UN -HEATED. Include a general note on the plans to show how the pipes will be protected from freezing. Also include any boring or drilling, if any, being done on the foundation to accommodate the plumbing for the washer, dryer and tub sink. 5. A Carbon Monoxide detector / Alarm is required on every floor of a home. Plans do not show a CO alarms on the main floor, Upper floor or the basement. Combination Smoke/CO alarms are an acceptable option. Section R315 Carbon Monoxide Alarms R315.2.2 Alterations, Repairs and Additions existing dwellings shall be equipped with carbon monoxide alarms in accordance with Section R315.2. 1. An inspection will occur where alterations, repairs, or additions requiring a permit occur, or where one or more sleeping rooms are added or created. 6. Please detail the use of the Mystery Spot. Also include and explanation of the "tiny access". Because this is an accessible space through the "tiny access" there are minimum sizes for the access and fire blocking concerns throughout that space if required. Page 5 7. Plans show arcadia door on south west side of building is to have a barrier until deck built. Include a detail of this "Barrier". Please assure the design complies with Section R312 Guards and Window Fall Protection R312.1 Guards Guards shall be provided in accordance with Sections R3 12. 1.1 through R312.1.4. R312.1.1 Where Required Guards shall be located along open -sided walking surfaces, including stairs, ramps and landings, that are located more than 30 inches measured vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. 8. Please include CFM for all bathroom fans. Also include the CFM for the kitchen and any other fans in the house. 9. Unable to locate the calculations for "4xl2" beam on the "upper floor/lower roof' detail, 10. The structural details are stamped by the EOR. However the changes made to the plans require the EOR to stamp those also. Please have the EOR review and stamp the appropriate pages. Page 6 11. Indicate height of porch on details. If hand rail and guard is required (> 30" from porch to ground) please include the details for guard and handrail as required. Page 2 of 3 12. Footing at porch does not indicate depth. The minimum frost line depth in the city of Edmonds is 18" ECDC 19.05.020 item 6. If you need any clarification or have any questions at all, please feel free to call anytime. Kevin Bloomfield Page 3 of 3