,,..I'(raZan & ASSOCIATES, INC.
GEOTECHNICAL ENGINEERING * ENVIRONMENTAL ENGINEERING
CONSTRUCTION TESTING & INSPECTION
FORENSIC INVESTIGATION
August 15, 2018
Building Official
CITY OF EDMONDS
121 5h Avenue North
Edmonds, WA 98020
RE: FINAL LETTER
Evavold Residence
10707 240' Place SW
Edmonds, WA
Krazan No. 096-18221
Permit No.: BLD2018-0459
In. accordance with your request and authorization, we have performed periodic special testing and
inspection services for the above referenced project. The special inspection for this project was:
0 Retrofit Hold Downs
To the best of our knowledge, the above referenced item have been found to be in general accordance with
the approved plans and specifications, at locations represented within Krazan reports only.
If you have any questions, or if we can be of further assistance, please do not hesitate to contact our office
at (425) 485-5519.
TES, INC.
Jeffrey
Pacifib Norrhwest Division
JSM/Ikm
CC: Jesse.evavold@gmail.com
4303 198' Street SW, Lynnwood, Washington 98036 - (425) 485-5519 - FAX (425) 485-6837
With Qfflces Serving the Western United States
Page 1 of I
QKmzan&Associates, I n c.
Geotechnical Engineering e Environmental Engineering
Construction Testing and Inspection
Field
Report NO.: 09618221DFR8142018JA
DATE: 8/14/2018 Set Count: CONTRACTOR: Mc Callum Cons
PROJECT #: 09618221 PERMIT #:
PROJECT: Evavold SFR INSPECTOR: Joseph Arams
LOCATION: 10707-2401h PL SW JURISDICTION: City of Edmonds
KA P.M.: Jeff Mercer WEATHER: Smoke TEMP: 71
Krazan & Associates, Inc. Arrive on site as requested for Adhesive Anchor Inspection. Contractor Use
S11VTSON Strong Tie SET-XP 10 Expiration Date 10/15/2019, 5/811 Diameter threaded rod,
embedment depth 10", Before they put the Epoxy they Clean the hole by air pressure, brush. A total of
17 holes Location of the Adhesive Anchor Inspection Hold dowels grid lines @ A-D/5,A/4-5,D/4-
5,4/A-D.
Reviewed By:
I ASTM Test#: I
I Asset Number(s):
I
To the best of my knowledge, the above WAS performed in accordance with the approved plans, specifications and
regulatory requirements.
Superintendent/Representative:
Technician:
Offices Serving the Western United States
Lynnwood (425) 485-5519 - Poulsbo (360) 598-2126 - Tacoma (253) 939-2500
The information provided on this report is preparod fu the caclusivc we ofthe client This report my not be reproduced in my fmunat without [be written permission ofthe client and Krazan & Associates. This report
indicates our inspoctors observation and testing results basod on site conditions and contractor activities. This information is subject to revim prior to final submittal. By skping this report, our inspector does not accept
responsibility fm� validity of results. Thesmeinf�tionhwb=pmidedbyathmmsite.