Loading...
4283_001.pdfOctober 24, 2018 ES-4937.02 Select Homes, Inc. 16531 — 13th Avenue West, A-1 07 Lynnwood, Washington 98037 Attention: Ms. Kayla Clark Subject: Response to Comments Proposed Short Plat 612 — 7th Avenue South Edmonds, Washington Reference: City of Edmonds Stormwater Review Comments Permit # BLD20180308, dated October 9, 2018 Earth Solutions NW, LLC Revised Geotechnical Engineering Study ES-4937.01, revised June 6, 2017 RAM Engineering, Inc. Civil Plans, dated February 28, 2018 Dear Ms. Clark: Earlh S S J�V tio olutions o NWLLE Earth Solutions NW LLC Geotechnical Engineering, Construction Observation[TesLing and Environmental Services As requested, Earth Solutions NW, LLC (ESNW) has reviewed the referenced plans and prepared this letter responding to City of Edmonds comments. The comments pertinent to the geotechnical aspects of the project are provided below followed by our response. City of Edmonds Comment 3 — It appears the east* drywell is within 50 feet of the landslide hazard area will require geotechnical approval; revise drywell location or submit documentation of geotechnical review and approval of the proposed revision. The western drywell is within 50 feet of the potential landslide area. ESNW will review under the assumption that the western drywell is the subject of review. 1805 - 136th Place N.E., Suite 201 * Bellevue, WA 98005 * (425) 449-4704 0 FAX (425) 449-4711 Select Homes, Inc. October 24, 2018 ES-4937.02 Page 2 ESNW Response — ESNW has reviewed the referenced plans. Based on our review, the plans conform to the recommendations and analyses in the referenced revised geotechnical engineering study prepared by ESNW and to the referenced sections of the ECDC. In our opinion, the infiltration surface of the drywell is located at a depth sufficient to not adversely affect the landslide hazard area. City of Edmonds Comment 4 — It appears the east* drywell is closer than five feet from the property line and exactly five feet from the proposed structure; revise plan to maintain required setbacks and/or provide additional geotechnical approval of reduced setback from proposed structure. The western drywell is within five feet of the proposed structure. ESNW will review under the assumption that the western drywell is the subject of review. ESNW Response — ESNW has reviewed the civil plans with respect to building setbacks. Based on our review, the reduced setback will not adversely affect the building foundation. ESNW should confirm footing setbacks during construction. We trust this response to comments letter meets your current needs. Should you have questions, or if additional information is required, please call. Sincerely, EARTH SOLUTIONS NW, LLC uel E. Suruda. G..T. Staff Geologist . Juow� of. IT C-3 7 1 AL 10 S'-A)t% Kyle R. Campbell, P.E. Principal Engineer cc: RAM Engineering, Inc. Attention: Mr. Rob Long (Email only) Earth Solutions NW, LLC