Loading...
4359_001.pdfMechanical Group Dynamic Solutions lor the Built Environment LETTER OF TRANSMITTAL Date: November 1, 2018 To: Chuck Miller Re- Permit Response Comments for BLD2018-1218 1st Review 22824 1 00th Ave West Anytime Fitness Mechanical System Chuck, Please find our permit response comments in RED in the following pages. Sincerely, Dylan Emde RESUB NOV 0 2 2018 BUILDING DEPARTMENT CITY OF EDMONDS te/-425.251.0356 1012 Central Ave. S. -KENT, WA 98032-5875 performancernechanicalgroup.corn City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: October 11, 2018 TO: Dylan Emde (IYI�iii.e(c�I)IIlfzllvilc.collI FROM: Chuck Miller, Senior Plans Examiner chuck. ni i I ler(c4edinondswa. Pov RE: Plan Check: BLD2018-1218 — 1" review Project Address: 22824 1 00th Avenue W Project: Anytime Fitness mechanical system Scope: HVAC and exhaust system for fitness facility — separated Assembly Group A-3 occupancy — 112 occupants — VB construction — NFPA 13 sprinkler system — plumbing, fire sprinkler, fire alarm, etc. under separate permits Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the 'clouded' or otherwise hit!hliphted chanaes can be found on the revised plans, have been submitted to a Permit Coordinator. Only those sheets specifically referenced as follows need to be resubmitted. Resubmittals must be made at the Development Services Department on the 2 d Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. General plan review comment: Provided Load 1. Provide as part of a complete permit application submittal design load calculations required Calculations to size the heating/cooling equipment per Washington State Energy Code (WSEC) C403.2.2. Mechanical plan 2. Provide as part of a complete permit application submittal a drawing representing the showing zoning and separate heating/cooling zones served by each piece of equipment, thermostat, and the exhaust has been ductwork serving them. It should also represent the means to be used to provide the exhaust submitted by others airflow rates for the restrooms and the storage/utility area per International Mechanical Code under BLD20181417. See (IMC) Table 403.3. 1.1 and the dryer exhaust per IMC Section 504. note 8 on M-1 On sheet I of 1: 3. Room Outside Air Vent. Requirements a. Room Classification — Clarify on the plans the following room (occupancy) classifications used to determine the minimum ventilation rates per IMC Table 403.3.1.1. This was a typo. Revised OSA * Dayeare - There does not appear to be a 'dayeare' use indicated on the calcs to show off ice space type. approved plans for the tenant improvement under pen -nit BLD2_0 18-0864. In addition, the 'occ. Num' and the 'CFM/person' does not appear to correspond with that typical for the use per IMC Table 403.3. 1. 1. Revised to reflect plans a Health Club / Weight Room — There appears to be other/different health club from BLD2018-0864 uses proposed on the plans for permit BLD2018-0864. Of particular concern are those activities/equipment (treadmills, cycle trainers, etc.) that result in higher respiratory rates, similar to that of aerobics. b. Room Area — Clarify on the plans the indicated square footage of the following areas used to determine the minimum ventilation rates per IMC Table 403.3. 1. 1. This was a typo. Revised OSA 0 Daycare — The indicated area is almost half of the total tenant space, far more calcs. than that of the non -fitness areas represented on the plans for permit BLD2018-0864. The area indicated for 'RTU-6' should only be that served by that equipment and its duetwork. Updated OSA calcs to reflect 9 Health Club / Weight Room — The indicated areas are, cumulatively, more zoning plan and occupant than 1200 square feet larger than the fitness areas represented on the plans for load plan. permit BLD2018-0864. The areas indicated for each piece of equipment should only be that served by each unit and its ductwork. Update the information on the provided table in response to the above plan review comments. Updated notes '1' and c. Notes '1' and '2' —Change on the plans the code regulating the fresh air requirements and the determination of the occupant loads from 'Washington State Energy Code' to 'IMC Table 403.3. 1. 1'. 4. Package Rooftop Heat Pump Updated OSA CFM to a. OSA CFM — Update the information for each of the units in response to plan review match fixed OSA calcs comments '3.a-c'. b. Notes Removed note i. Note 3 - Clarify on the plans the applicability of 'Note 3' for each of the units. None of the units appear to utilize fuel gas. See notes 1 and 6 ii. Note 5 — Add to the note on the plans the requirements that the modulating OSA and return dampers are configured to provide up to 100% OSA for cooling and to automatically reduce the outdoor air intake to the minimum ventilation rate complying with IMC Table 403.3. 1. 1 when the outdoor air will no longer reduce cooling energy usage per WSEC C403.3.1 and C403.3.3. See notes 11 and 12 iii. Note 6 — Add to the note on the plans the required capability and configuration of the existing thermostats to meet the requirements of WSEC C403.2.4. See note 2 iv. Note 7 — Change on the plans the referenced table regarding the minimum efficiency requirements of the equipment from 'C403.2.3 (I)A' to 'WSEC C403.2.3(2)'. Page 2 of 3 v. Note 8 — Add to the note on the plans the required installation of a thermostat that does not allow simultaneous heating and cooling in the same zone, has multiple cooling stage capability that will activate the economizer when appropriate as the first stage of cooling, and can adjust the equipment start time required to bring the area served up to the design temperature just prior to the scheduled occupancy of the area, per WSEC C403.2.4. 1. Added structural 5. Roof Plan attachment a. Provide on the plans details, and references to them, specifying the minimum details to M-2 required attachment (equipinent-to-curb/curb-to-roof) of each of the units to resist lateral loads per American Society of Civil Engineers (ASCE) 7-16, Chapter 13. The sections/details, found in the structural calculations prepared by PCS Structural Solutions — Project 18-646, must be incorporated into these plans to guide proper construction and inspection of the following: ' Section 3', found on page 4 'Section 5', found on page 6 'Section 7', found on page 8 Structural calculations have Other drawings/sections/details contained in the structural calculations intended to been sent to the GC in represent/specify those structural elements required to be altered and/or added to the order to submit a revision on BLD2018-0864 roof framing to support the mechanical equipment (such as each 'Roof Framing Plan' and the sections referenced therein) must be added as a revision to the plans for permit BLD2018-0864. Roof plan now points to b. Change on the 'Roof Plan' the locations of the equipment attachment and roof M-2 as the location of framing upgrade details referenced in the notes to that designated for those items the attachment details provided in response to plan review comment '5.a. c. General Notes — Note 3 - Change in the note the location of the roof framing plan/upgrade details from 'structural calculations' to 'approved plans for BLD2018- 0864'. Page 3 of 3