Loading...
4787_001.pdf12/12/2018 HOUSE REMODEL. City of Edmonds, WA Building Permit Application # BLD2018-1347 1023 CAROL WAY Edmonds, WA Subject: BUILDING PLANS REVIEW#1 Dear, Eric Evensen We are writing this letter, so that we may in greater depth explain our response to your requests. Wewill attempt to explain how and where you question, we addressed. The changes on the plan were clouded for greater clarity. Building plans review 1. Scope of Work — Please resolve the apparent conflict between submitted application materials. Note that existing plumbing fixtures having no work done on them or plumbing fixtures being replaced at the same location, do not require a permit: a. Online Plumbing Application and Building Permit Application show: - 2 Toilets (WC) - 5 Sinks - 3 Tub/Showers - I Water Service Line - 1 Dishwasher - I Outside Faucet - 1 Clothes Washer - I Water Heater - I Stove/Range - 1 Dryer - 2 Gas Fireplaces b. Submitted drawings show: - I Toilet at a new location - 2 Sinks in new locations - 2 Tub/Showers in new locations Response: The existing and proposed plan have been revised. The plumbing fixtures have been named and shown as New and Existing. On the Building Plans: 1. On the plans, identify each gas appliance as "NEW" or "EXISTING". Response: The appliance has been identified as NEW and EXISTING 2. Alterations — Alterations shall comply with the provisions the Washington State Energy Code (WSEC) Table R402. 1.1 without requiring the entire structure to comply, per WSEC R503. 1. On the plans: a. Identify each window or skylight as "NEW" or "EXISTING." New windows shall have a maximum U-factor of 0.30. Response: Each window and skylights have been identified as EXISTING. The note has been posted: that "'the newwindowsshall havea maximum U-factor of 0.30" b. Identify new ceilings as having minimum R-factor of 49. Response- The, ceilings: insulation have been shown on the� plan and note: "Insulation has to be R-49" c. Each new or replacement skylight shall have a maximum U-factor of 0.50. Response: The note has been placed on the sheet. d. Exposed exterior wall cavities shall be insulated with minimum R- 15 insulation. Response: The note has been placed on the sheet. 3. Replacement windows — Provide or maintain emergency egress and escape openings in the east and west bedrooms. Per R310.2.5 (IRC Errata posted June 10, 2015) replacement windows are exempt from maximum sill height of R3 10.1 and R310.2.1 and R310.2.2, provided the replacement window meets the following conditions: a. It is the manufacturer's largest stand size window that will fit within the existing frame or existing rough opening Response: The egress windows have been identified. The evacuation note has been placed on the sheet A04. The note:" the manufacturer's largest stand size window that will fit within the existing frame or existing rough opening" has been added on the sheet A04. b. It is the same operating style as the existing window or a style that provides for an equal or greater window opening area than the existing window. Response: The note has been placed on the sheet A04 4. To evaluate the proposed new beams, provide an existing fi-aming plan to scale. Show existing roofjoist layout. Indicate point loads and bearing walls below. Verify 4 x 6 ceiling joists and spacing. Also, please address in calculations. Response,: The beam schedule hasbeen placed on sheetA04. The proposed new beams, have been shown on the roof plan sheet A05. The sheet A05 -roof plan has been added to the set. The existing roof plan layout has been provided on the sheet A03.1. The existing main floor plan provided on sheet A03. There bearing wall shown on the existing and proposed floor plans. The existing, and proposed ceilingjoists are 2x:6. The spacing shown where it was verified. 5. New shower in North Bedroom Bath — Locate control valves and showerheads so that the bather can adjust the valves prior to stepping into the shower spray, per Uniform Plumbing Code (UPC) 408.9. Response- Theshowerheads andvalves have been,shown. 6. Reroofing — Note reroofing on the plans. Response: The note: "Reroofing "has been placed on the roof plan sheet A05 Tatyana Shadyrya Archstudlo"'Y.Shadyrya" 206 240-7329 yshadyrya@yahoo.com