4850_001.pdfDecember 19, 2018
Corrections Response
1. Side sewer is shown on site plan
2. Pool cannot be drained (Shown on plan)
3. Fill location or spigot is shown on plan along with anti syphon device
Setbacks
1. Pool location moved to Tolf rear property line.
Pool Equipment
1. No pool equipment located within 7,5'of side property line
k0V E0.1,
CITY OF EDMONDS
PLAN REVIEW COMMENTS
PLANNING DIVISION
425.771.0220
DATE: 11/16/2018
TO: Jim Berstrom
ibei-L,sti-()inte-i)ggtiaguip.coiii
FROM: Amber Groll, Planner
qniberj,
[�ILI(ib�dmondswajwtov
RE: Plan Check BLD2018-1481
8101 208" PI SW
Install Pool & Patio
On behalf of the Planning Division, I have reviewed the above building permit application. During
review of the subject submittal, it was found that the following information, corrections, or clarifications
need to be addressed. Please respond to the following items, so that I can complete my review:
1. Setbacks:
a. The setbacks for the RS-8 zone is a 25 foot minimum from a street, 7.5 foot minimum
from the side property lines, and a 15 foot minimum from the rear property line. It
appears that the proposed pool and patio will encroach into the rear property line setbacks
on the northern side of the lot. Per ECDC 16.20.050.C, the pool edge may be on the rear
setback line of 15 feet. If the patio is less than 30" above ground level, it may project into
the required setback not more than one-third of the required setback or four feet,
whichever is less. Please provide an updated site plan with corrected setbacks.
2. Pool equipment:
a. Minimum required side setbacks for the RS-8 zone as applied to the subject site are 7.5
feet. Improvements of a minor character less than 3 feet in height are excluded from side
setbacks. Any mechanical equipment placed within the setbacks must be less than 3 feet
in height including the height of the pad. The current site plan shows the pool equipment
within the side setback, however, height dimensions were not included in the provided
plans. Please clarify the equipment height.
If you have any questions, feel free to contact me at 425.771.0220 ext. 1372.
Please make all submittals to a Development Services Permit Coordinator, Monday, Tuesday, Thursday,
and Friday between 8:00 am 4:30 pm or Wednesday 8:30 am to 12:00 pm.
0
CITY OF EDMONDS
PLAN REVIEW COMMENTS
ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.goy
DATE: December 4, 2018
TO: Jim Bergstrom
jbergstromgaquaquip.com
FROM: Natalie Griggs, Engineering Technician
Natalie.griggs@edmondswa.gov
RE: Application #: BLD20181481
Project: Weller Residence
Project Address: 8101 208" PI SW
During review of the above noted application, it was found that the following information,
corrections, or clarifications are needed. Please submit revised plans/documents including a written
response to each item below.
Resubmittals can be made at the Development Services Department on the 2 nd floor of City Hall.
Permit Center hours are M, T, Th & F from 8am-4:30pm and on Wednesdays from 8:30am-noon.
City of Edmonds handouts, new updated standard details with new reference numbers, application
and other forms, and development code may be referenced on the City website:
ww".%edmondswa.gov under Services/Permits and Development.
GENERAL
1. Please show the location of the existing side sewer on the site plan.
2. Please show how the pool will be drained on the plans.
a. Please note that pools cannot have a direct connection to sanitary sewer.
3. Please show the fill location for the pool on the site plan (typically a spigot on the outside of
the house).
a. Please note that an AVB will need to be installed at this location.
b. Please revise the plans accordingly.