70Ave N - 15723_Huebner SFR_BLD20080306.pdfCity of Edmonds 121 5TH AVENUE NORTH EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us PUBLIC WORKS DEPARTMENT Engineering Division Engineering Plan Review Comments Application #: BLD20080306 Date: August 16, 2008 Project Name/Address: Huebner SFR / 15723 - 70 Ave N Contact Person/Address, Fax or E-mail: Cameron Huebner / CWHUEBNERA_HOTMAIL.COM Reviewer: Edward Sibrel Division: Engineering During review of the civil drawings for the proposed subdivision it was found that the following information, corrections, or clarifications will need to be addressed. Please resubmit 3 copies of the revised civil drawings and associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220 or by e-mail at sibrel(a),ci.edmonds.wa.us if you have specific questions regarding these plan corrections. Engr Review 1 - 5/21/08; Review 2 - 07/16/08; Review 3 —August 16, 2008 1. OK 2. OK 3. OK 4. The detention and drainage system is not adequately represented on the site plan: a. OK b. OK c. OK d. OK e. Detention and storm conveyance pipe material must be specified. Info only: Although technically allowed, the City discourages the use of CMP for drainage purposes. f. OK g. Since the storm line is proposed to be buried under a driveable surface, minimum pipe coverage must be 2 feet. Detention pipe coverage at upper detention catch basin is less than 2 feet. h. New Item: Proposed slope of detention pipe is double the allowed maximum. DATE E-MAILED 8/16/08 PAGE(s) 1 of 2 City of Edmonds 121 5TH AVENUE NORTH EDMONDS, PUBLIC WORKS DEPARTMENT Engineering Division WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmondsma.us Engineering Plan Review Comments i. New Item: Proposed rim elevation for upper catch basin, which is three feet from the garage, is three feet below the garage finished floor elevation. Please review and adjust. j. New Item: The rim elevation for the control catch basin is almost seven feet above the upper catch basin. Please review and adjust. 5. OK 6. OK 7. OK 8. a. OK b. The side sewer is proposed to connect directly to a nearby sewer manhole. Please specify how this is to be accomplished. Applicant replies: When the sewer line was put in roughly 23 years ago, a stub out at that location was put in by the city by Ed Huebner's request. Please add a note to the drawing to contact Public Works at 425.771.0235 to ascertain that the direct side sewer/manhole connection is at current standards. 9. Please note the location in the 70th Ave right-of-way where the proposed water meter is to be located. Please clarify: is this an existing water meter? Is the service line already stubbed to the property? DATE E-MAILED 8/16/08 PAGE(s) 2 of 2