bld 20061106a and 1107 bldg 6-7 plumbing.doc City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Comments Plan Check : Date: # BLD 20061106 & 1107 23 Oct 06 Project Name/Address: Pt. Edwards: 31 and 41 Pine St Contact Person/Address/Fax: fax/e-mail : Ross Woods : ross@triaddev.com Reviewer: Division:Engineering Lyle Chrisman, Engineering Program Manager The subject application has been reviewed but cannot be completed until the following items have been addressed/corrected. Please resubmit 3 sets of revised drawings to a Development Services Permit Coordinator. 1. Based on the inverts provided, the main 4” run has only a 0.9% slope and the 6” portion of the run is only 0.65%. The minimum slope for 4” is 2% and 6 inch is 1%. As stated in my previous comments, earlier discussions with Longitude 122, they stated the minimum 2% grade could not be achieved and that an 8” would be used the entire run in order to get sufficient flow to the sewer manhole. Please coordinate with Longitude 122 on this issue and correct as required. __________________(Attach fax transmittal) DATE FAXED PAGE ____ OF ___ C:\\Users\\mcadmin\\AppData\\Local\\Temp\\bld 20061106a and 1107 bldg 6-7 plumbing.doc_154327\\bld 20061106a and 1107 bldg 6-7 plumbing.doc