BLD20070198-9 Westgate Arms 9804-8 Edmonds Way REV.doc MEMORANDUM Date:March 15, 2007 To:Development Services Lead Theresa Umbaugh From:John Westfall, Fire Marshal (425) 771-0213 Subject:BLD20070198-9 Westgate Arms Condos 9804-8 Edmonds Way The Fire Department provides the following comments and corrections in accordance with the 2003 International Fire Code and Edmonds Community Development Code: 1. Add General Note: Pre-sales or “model showing of units” is defined by the Fire Department as a “use” of a building or premises and is inherently hazardous to the public prior to issuance of a certificate of occupancy. Pre-sales or model showing shall not be allowed without a (permanent or) temporary certificate of occupancy and Fire Department permit. Emergency plans as outlined by IFC Chapters 4 or 14 and local safety standards must be met for approval of temporary certificate. No building or structure shall be used or occupied until that certificate of occupancy, or temporary certificate is issued. IFC 901.5.1 2. Will construction be performed while occupied? Arrange preconstruction meeting with FD (425- 771-0213) and willing city departments to identify safety considerations, and eliminate life safety and habitability impacts for existing tenants. 3. Add note: Clear brush and remove landscaping plants from private hydrants so that visual contact can be made for a distance of 50’ upon approach. 4. Are any changes proposed for parking/access area? Provide existing/proposed plan for parking/access. 5. Add note: Under stair storage is required to be 1-hr fire resistive. Show any work required for this performance. 6. Add note: Interior finish treatments are required to meet IBC 803 for flame-spread index and smoke developed index. Callout new furnishings and treatment to meet class B for (non- sprinklered) exit passageways, access corridors, and other exits, as well as class C for room and other enclosed spaces. 7. Sheet 4: scale plan 8. Provide illuminated exit signs indicating path of exit no more than 100’ distant from next exit sign. City of Edmonds Office of Fire Marshal   9. Provide emergency illumination throughout common living, activity, and egress areas. 10. Provide 2A:10B:C min. rated portable fire extinguishers on each level near each exit so that no living area is more than 75’ travel distance to closest fire extinguisher. IFC Section 906 11. Sheet 6 clearly identify plans as existing, proposed, etc.. 12. Call out permits/submittals required on cover sheet: Fire Alarm, Fire Protection Footprint, Life Safety & Evacuation Plan. a. Fire Alarm Permit Fire alarm system is required throughout for the purposes of off- site sprinkler system monitoring, local alarm audible/visual notification, exterior audibility, and single manual pull located in lobby. IFC 903.4.2 b. Fire Protection Footprint is required (attached). c. Fire Safety & Evacuation Guide Provide a guide which describes the location, function and use of fire protection equipment and appliances accessible to residents, including fire alarm systems, smoke alarms, and portable fire extinguishers in R2 apartments and condominiums. Email westfall@ci.edmonds.wa.us for example. IFC 408.9 13. Provide Fire Department lockbox. Coordinate with Fire Department for a “Lockbox Authorization Letter” and instructions to obtain and install lockbox outside the sprinkler rooms on your site. 425.775.7720 14. Sheet ID01: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their installed background. Address numbers shall be Arabic numerals or alphabet letters. Numbers will be required both on north elevation of building for street visibility and east elevation for parking lot visibility. 15. Add note: Replace dwelling smoke alarms with new throughout. Local alarms shall be interconnected within dwelling with battery backup. Call out smoke alarms on sheet ID2:Unit RCP. 2 Attachment: Fire Protection Footprint Cc: Michael Trower; Catapult Development, mtrower@catapultdevelopment.com Assistant Building Official Ann Bullis 3