BLD20070447-1.pdf City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections Application : Date: # BLD20070447 May 22, 2007 Project Name/Address: Eaglewood Homes Inc. / 915 Cedar Street Contact Person/Address/Fax/e-mail: Craig Reimer / 18607 OVD/ 425-771-6822 / Fax: 425-775-8395/ e- mail: rimetime@comcast.net Reviewer: Jaime HawkinsDivision:Engineering During review of the above noted application, it was found that the following information, corrections, or clarifications are needed. Please submit three (3) sets of revised plans/documents with a written response to each of the items below to a Permit Coordinator. JoAnne Zulauf is your City contact for this project. 1.Please call out the standard details for the proposed curb/gutter, and sidewalk (E2.8, and E2.13) respectively. 2.Please show and call out the driveway cut to be installed per City of Edmonds standard detail E2.26 3.The sanitary sewer shall have a 6” cleanout installed on the street side at the property line with a 12” CI locking lamphole cover at finished grade. The side sewer can be 4” from the property line to the house. A 4” cleanout is required at the house. Please show these requirements on the plans. th 4.Please show the existing catch basin at the NE corner of 9Ave S and Cedar ST. Make sure to include rim and invert elevations. This must be shown in all three plans, Site, Grading and Drainage. 5.Please call out the required catch basin protection per City of Edmonds standard detail E1.3 on all existing structures. 6.Provide tom and bottom elevation for the concrete wall along the north property line. Is this wall existing or proposed? Please indicate. 7.Please call out the storm pipe diameter from the detention system to the proposed catch basin. 8.The minimum storm pipe diameter to be used in the Right-of-Way shall be 12-in. Please call out and show the pipe and diameter from the proposed catch basin to the existing catch basing located at the Northeast th corner of 9 Ave S and Cedar St. 9.The minimum distance from the proposed face of curb to the painted road centerline shall be 12-ft. If the there is not a painted road centerline then you shall measure from the crown of the road. Please show the painted road centerline, if one exists, otherwise show the crown of the road. Please contact me at 425-771-0220 or by e-mail at hawkins@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. DATE E-MAILED 5/22/07 PAGE 1 of 1